29 |
ELECTRICAL ENGINEERING |
Electrical engineering in general |
|
| MS 406 : 1996 | |
| Specification for voltages and frequency for alternating current transmission and distribution system (Second revision). | |
| This revised Malaysian Standard covers the voltages and frequency recommended for alternating-current transmission and distribution systems. This standard shall supersede MS 406 : 1989. | |
| Price Code : A | |
| MS 472 : Part 2 : Sec. 2.9 : 1983 | |
| Specification for testing and approval of household and similar appliances : Part 2 : Section 2.9 : Particular requirements for rice cooker. | |
| Specifies requirements for rice cooker for use in household and does not apply to commercial rice cooker. Should be read in conjunction with MS 472 : Part 1. | |
| Price Code : A | |
| MS 472 : Part 2 : Sec. 2.11 : 1987 | |
| Specification for testing and approval of household and similar appliances : Part 2 : Particular requirements : Section 2.11 : Floor treatment and wet scrubbing machines for household and similar purposes. | |
| This section applies to floor treatment machines, such as floor polishers, floor waxers, and floor buffers, and wet scrubbing machines, such as rug shampooers, floor scrubbers, and upholstery shampooers, all intended for household and similar use. It does not apply to sanding machines. | |
| Price Code : B | |
| MS 472 : Part 3 : Sec. 3.1 : 1986 | |
| Specification for testing and approval of household and similar appliances : Part 3 : Complete particular specifications : Section 3.1 : Stationary instantaneous water heaters. | |
| This standard specifies requirements for electric stationary instantaneous water heaters for heating water to a temperature below its boiling point for household and similar purposes. Both sheathed and bare heating element types are covered. It does not take into account the special hazards that exist in nurseries and other places where there are young children or aged or infirm persons without the supervision : in such cases additional requirements may be necessary. | |
| Price Code : K | |
| MS 860 : Part 1 : 1983 | |
| Specification for power supply units for extra low voltage output : Part 1: Units for indoor use. | |
| Provides definitions, classification, ratings, construction, output and test methods of various safety requirements for current reducing power units for operating toys using electric supply. | |
| Price Code : B | |
| MS 944 : 1984 | |
| Specification for maximum demand indicators class 1.0. | |
| Covers definitions, classification, mechanical and electrical requirements, marking, accuracy for above indicators intended to operate as attachments to watthour meters or varhour meters. Does not apply to indicators based on thermal effects or those operated by impulses, not to cumulative indicators. | |
| Price Code : B | |
| MS 946 : 1984 | |
| Specification for residual current operated protective device. | |
| Definitions, service conditions, rating and marking, design and construction and type and routine test are outlined. Rated voltage of device does not exceed 660 Volts, while rated current does not exceed 125 amp. at rated frequency not exceeding 400Hz. | |
| Price Code : C | |
| MS 1144 : 1998 | |
| Specification for general requirements for electrical accessories. | |
| Covers requirements for electrical wiring accessories for installation not specifically covered by other Malaysian Standards for use in single phase a.c. or d.c. circuits for voltages between conductors, exceeding extra-low voltage but not exceeding 250 V and current not exceeding 45A. | |
| Price Code : D | |
| MS 1487 : 1999 | |
| Electrotechnical vocabulary : Chapter 121 : Electromagnetism | |
| Gives electrotechnical definitions related to electromagnetism. | |
| Price Code : C | |
| MS 1538 : 2002 | |
| Specification for speed monitoring device for road vehicles | |
| This Malaysian Standard specifies minimum construction requirements, performance, test requirements and marking of devices designed to monitor and record the road speed and speeding and tampering violation of motor vehicles. | |
| Price Code : I | |
| MS CISPR 14-2 : 2000 | |
| Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2 : Immunity - Product family standard | |
| Deals with the electromagnetic immunity of appliances and similar apparatus for household and similar purposes that use electricity, as well as electric toys and electric tools, the rated voltage of the apparatus being not more than 250 V for single-phase apparatus to be connected to phase and neutral, and 480 V for other apparatus. This standard is identical with CISPR 14-2 : 1997. | |
| Price Code : C | |
| MS CISPR 19 : 2000 | |
| Guidance on the use of the substitution method for measurements of radiation from microwave ovens for frequencies above 1 GHz | |
| Describes a method of measurement for small microwave ovens (largest dimension less than 1 m) and a separate method of measurement for large microwave ovens (largest dimension exceeding 1m). This standard is identical with C.I.S.P.R. Publication 19 : 1983. | |
| Price Code : A | |
| MS IEC 60050-426 : 2004 | |
| International electrotechnical vocabulary Electrical apparatus for Chapter 426 : explosive atmospheres | |
| Price RM30 | |
| MS IEC 60065 : 1997 | |
| Safety requirements for mains operated electronic and related apparatus for household and similar general use. | |
| Price Code : N | |
| MS IEC 60364-7-702 : 2003 | |
| Electrical installations of buildings Part 7: Requirements for special installations Section 702: Swimming pools and other basins (First revision). | |
| This Malaysian Standard is identical with IEC 60364-7-702:1997. This Malaysian Standard applies to the basins of swimming pools, the basins of fountains and the basins of paddling pools. They also apply to the surrounding zones of all these basins. In these areas, in normal use, the effect of an electric shock is increased by a reduction in body resistance and contact of the body with earth potential. The requirements for swimming pools are applicable for paddling pools. This Malaysian Standard cancels and replaces MS IEC 60364-7-702:1996. | |
| Price Code : B | |
| MS IEC 61000-3-2 : 2000 | |
| Electromagnetic compatibility (EMC) - Part 3 : Limits - Section 2 : Limits for harmonic current emissions (equipment input current less than or equal to 16 A per phase ) | |
| Applicable to electrical and electronic equipment having an input current up to and including 16 A per phase, and intended to be connected to public low-voltage distribution systems. The tests specified this standard are type tests.Test conditions for particular equipment are given in Annex C. For systems with nominal voltages less than 220 V (line to neutral), the limits have not yet been considered. This standard is identical with IEC 61000-3-2 : 1995 | |
| Price Code : C | |
| MS IEC 61000-3-3 : 2000 | |
| Electromagnetic compatibility (EMC) - Part 3 : Limits - Section 3 : Limitation of voltage fluctuations and flicker in low-voltage supply systems for equipment with rated current less than or equal to 16 A | |
| Relates with the limitation of voltage fluctuations and flicker impressed on the public low-voltage system. The standard specifies limits of voltage changes which may be produced by an equipment tested under specified conditions and give guidance on methods of assessment. | |
| Price Code : C | |
| MS IEC 61000-3-5 : 2000 | |
| Electromagnetic compatibility (EMC) - Part 3 : Limits - Section 5 : Limitation of voltage fluctuations and flicker in low-voltage power supply systems for equipment with rated current greater than 16 A | |
| Concerns with the emission of disturbances due to voltage fluctuations and flicker. The recommendations are applicable to electrical and electric equipment intended to be connected to a public low-voltage a.c distribution system, where the equipment has a rated input current exceeding 16 A per phase, or has a lower rated current, but requires the special consent of the supply authority. This standard is identical with IEC 61000-3-5 : 1994. | |
| Price Code : B | |
| MS IEC 61000-4-2 : 2000 | |
| Electromagnetic compatibility (EMC) Part 4 : Testing and measurement techniques Section 2 : Electrostatic discharge immunity test Basic EMC publication | |
| Relates to the immunity requirements and test methods for electrical and electronic equipment subjected to static electricity discharges, from operators directly, and to adjacent objects. The standard also defines ranges of test levels which relates to different environmental and installation conditions and establishes test procedure. This standard is identical with IEC 61000-4-2 : 1995. | |
| Price Code : D | |
| MS IEC 61000-4-3 : 2001 | |
| Electromagnetic compatibility (EMC) - Part 4 : Testing and measurement techniques - Section 3 : Radiated, radio-frequency, electromagnetic field immunity test (First revision). | |
| This section of MS IEC 1000-4 is applicable to the immunity of electrical and electronic equipment to radiated electromagnetic energy. It establishes test levels and the required test procedures. The object of this section is to establish a common reference for evaluating the performance of electrical and electronic equipment when subjected to radio-frequency electromagnetic fields. This standard superseded MS IEC 61000-4-3 : 2000. | |
| Price Code : E | |
| MS IEC 61000-4-4 : 2000 | |
| Electromagnetic compatibility (EMC) Part 4 : Testing and measurement techniques Section 4 : Electrical fast transient/burst immunity test Basic EMC publication | |
| Relates to the immunity requirements and test methods for electrical and electronic equipment to repetitive electrical fast transients. Additionally defines ranges of test levels and establishes test procedures. The object of this standard is to establish a common and reproducible basis for evaluating the performance of electrical and electronic equipment when subjected to repetitive fast transients (burst), on supply, signal and control parts. This standard is identical with IEC 61000-4-4 : 1995. | |
| Price Code : D | |
| MS IEC 61000-4-5 : 2000 | |
| Electromagnetic compatibility (EMC) - Part 4 : Testing and measurement techniques - Section 5 : Surge immunity test | |
| Relates to the immunity requirements, tests methods, and range of recommended test levels for equipment to unidirectional surges caused by overvoltages from switching and lightning transients. Several test levels are defined which relate to different environment and installation conditions. These requirements are developed for and are applicable to electrical and electronic equipment. Establishes a common reference for evaluating the performance of equipment when subjected to high-energy disturbances on the power and inter-connection lines. This standard is identical with IEC 61000-4-5 : 1995. | |
| Price Code : E | |
| MS IEC 61000-4-6 : 2000 | |
| Electromagnetic compatibility (EMC) - Part 4 : Testing and measurement techniques - Section 6: Immunity to conducted disturbances, induced by radio-frequency fields | |
| Relates to the conducted immunity requirements of electrical and electronic equipment to electromagnetic disturbances coming from intended radio-frequency (RF) transmitters in the frequency range 9 kHz up to 80 MHz. Equipment not having at least one conducting cable (such as mains supply signal line or earth connection) which can couple the equipment to the disturbing RF fields is excluded. This standard is identical with IEC 61000-4-6 : 1996. | |
| Price Code : E | |
| MS IEC 61000-4-7 : 2000 | |
| Electromagnetic compatibility (EMC) Part 4 : Testing and measurement techniques Section 7: General guide on harmonics and interharmonics measurements and instrumentation, for power supply systems and equipment connected thereto | |
| Applicable to measurement instrumentation intended for testing individual items of equipment in accordance with emission limits given in standards (e.g. harmonic current limits as given in IEC 555-2) as well as for the measurement of harmonic voltage and currents in actual supply systems. The survey of harmonics in the power supply systems is of particular concern. This standard is identical with IEC 61000-4-7 : 1991. | |
| Price Code : D | |
| MS IEC 61000-4-8 : 2000 | |
| Electromagnetic compatibility (EMC) Part 4 : Testing and measurement techniques Section 8 : Power frequency magnetic field immunity test Basic EMC publication | |
| Relates to the immunity requirements of equipment, only under operational conditions, to magnetic disturbances at power frequency related to: - residential and commercial locations;- industrial installation and power plants; - medium voltage and high voltage sub-stations. This standard does not consider disturbances due to capacitive or inductive coupling in cables or other parts of the field installation. This standard is identical with IEC 61000-4-8 : 1993. | |
| Price Code : D | |
| MS IEC 61000-4-10 : 2000 | |
| Electromagnetic compatibility (EMC) - Part 4 : Testing and measurement techniques - Section 10 : Damped oscillatory magnetic field immunity test Basic EMC publication | |
| Relates to the immunity requirements of equipment, only under operational conditions, to damped oscillatory magnetic disturbances related to medium voltage and high voltage sub-stations. This standard does not consider disturbance due to capacitive or inductive coupling in cables or other parts of the field installation. This standard is identical with IEC 61000-4-10 : 1993. | |
| Price Code : D | |
| MS IEC 61000-4-11 : 2000 | |
| Electromagnetic compatibility (EMC) - Part 4 : Testing and measuring techniques - Section 11 : Voltage dips, short interruptions and voltage variations immunity tests | |
| Defines the immunity test methods and range of preferred test levels for electrical and electronic equipment connected to low-voltage power supply networks for voltages disp, short interruptions, and voltage variations. The standard applies to electrical and electronic equipment having a rated input current not exceeding 16 A per phase. It does not apply to electrical and electronic equipment for connection to d.c. networks or 400 Hz a.c networks. This standard is identical with IEC 61000-4-11 : 1994. | |
| Price Code : C | |
| MS IEC 61000-4-12 : 2000 | |
| Electromagnetic compatibility (EMC) Part 4 : Testing and measurement techniques - Section 12 : Oscillatory waves immunity test Basic EMC publication | |
| Relates to the immunity requirements and test methods for electrical and electronic equipment, under operational conditions, to oscillatory waves represented by: a) no-repetitive damped oscillatory transients (ring wave) occurring in low-voltage power, control and signal lines supplied by public and non-public networks. b) repetitive damped oscillatory waves occurring mainly in power, control and signal cables installed in high voltage and medium voltage (HV/MV) stations. This standard is identical with IEC 61000-4-12 : 1995. | |
| Price Code : E | |
| MS IEC 61000-4-16 : 2000 | |
| Electromagnetic compatibility (EMC) - Part 4-16 : Testing and measurement techniques - Test for immunity to conducted, common mode disturbances in the frequency range 0 Hz to 150 KHz | |
| Relates to the immunity requirements and test methods for electrical and electronic equipment to conducted common mode disturbances in the range d.c to 150 kHz. The object of this standard is to establish a common and reproducible basis for testing electrical and electronic equipment with the application of common mode disturbances to power supply, control, signal and communication parts. This standard is identical with IEC 61000-4-16 : 1998. | |
| Price Code : C | |
| MS IEC 61000-6-1 : 1997 | |
| Electromagnetic compatibility (EMC) - Part 6 : Generic standards - Section 1 : Immunity for residential, commercial and light-industrial environments | |
| Applies to electrical and electronic apparatus intended for use in the residential, commercial and light-industrial environment, as described in clause 4, for which no dedicated product or product-family emission standard exists designed to radiate. Disturbances in the frequency range O Hz to 400 GHz are covered. This standard is identical with IEC 61000-6-1 : 1997. | |
| Price Code : B | |
| MS IEC 61000-6-3 : 2000 | |
| Electromagnetic compatibility (EMC) - Part 6 : Generic standards - Section 3 : Emission standard for residential, commercial and light-industrial environments | |
| Applies to electrical and electronic apparatus intended for use in the residential, commercial and light industrial environment, as described in Clause 5, for which no dedicated product or product-family emission standard exists. Apparatus designed to radiate electromagnetic energy for radio communication purposes is excluded from the standard. Disturbances in the frequency range 0Hz to 4000 GHz are covered. This Standard is identical with IEC 61000-6-3 : 1996. | |
| Price Code : B | |
| MS IEC 61000-6-4 : 2000 | |
| Electromagnetic compatibility (EMC) - Part 6 : Generic standards - Section 4 : Emission standard for industrial environments | |
| Applies to electrical and electronic apparatus intended for use in the industrial environment, as described in Clause 5, for which no dedicated product or product-family emission standard exists. Apparatus designed to radiate electromagnetic energy for radio communication purposes is excluded from this standard. Disturbances in the frequency range 0Hz to 400 GHz are covered. Fault conditioning of apparatus are not taken into account. Also applies to apparatus intended to operate in industrial locations or in proximity to industrial power installations. This standard is identical with IEC 61000-6-4 : 1997. | |
| Price Code : B | |
Insulating materials |
|
Insulating materials in general |
|
| MS 938 : 1984 | |
| Specification for classification of materials for the insulation of electrical machinery and apparatus in relation to their thermal stability in service. | |
| Classifies insulation into seven classes according to materials and details out information on ratings, assessment of thermal stability and application. | |
| Price Code : B | |
Conducting materials |
|
| MS 69 : 1995 | |
| Specification for conductors in insulated cables and cords (Second revision). | |
| This Malaysian Standard specifies the nominal cross-sectional areas and requirements, including numbers and sizes of wire and resistance values, for conductors in electric cables and cords of a wide range of types. These conductors include solid and stranded copper and aluminium conductors' 'in cables for fixed installations and flexible copper conductors'. | |
| Price Code : D | |
| MS 1142 : 1989 | |
| Specification for hard-drawn copper and power copper-cadmium conductors for oven-head transmission purposes. | |
| Specifies requirements for hard-drawn copper and copper cadmium solid and stranded circular conductors for overhead power transmission systems. | |
| Price Code : B | |
| MS 1143 : 1989 | |
| Specification for aluminium alloy stranded conductor for overhead power transmission. | |
| Covers requirements for heat-treated aluminium-magnesium-silicon alloy stranded conductors for overhead power, transmission; values for physical properties, sizes of wires and of stranded conductors; torerances on dimensions, mechanical properties and electrical resistivity; modules of elasticity and code names for use when ordering. | |
| Price Code : B | |
Electrical wires and cables |
|
| MS 280 : 1975 | |
| Specification for copper for electrical purposes, wire for general electrical purposes for insulated cables and flexible cords. | |
| Specifies requirements for high conductivity, plain or tinned, annealed or hard copper wire with diameter from 0.05 mm up to and including 6.6. mm for general electrical purposes and for use in insulated cables and flexible cords. | |
| Price Code : B | |
| MS 1540 : 2002 | |
| Specification for the material, marking and dimensions of crimp type cable lugs for use with copper conductors in low voltage applications | |
| This Malaysian Standard specifies the overall installed dimensions of crimp type cable lugs (copper conductors) for low voltage applications. Dimensions are provided for the full length, barrel length, internal diameter of barrel, thickness of barrel, clearance hole for bolt mounting and chamfer on the lug barrel. This standard also provides guidelines for material specification, finishing and cable lug markings. This standard applies to terminal lugs for the conductors of power cables and secondary wiring with cross-sections 1.5 mm2 to 1000 mm2 for copper conductors. This standard is also limited to cable lugs for low voltage applications i.e. up to a maximum of 1 kV. This standard is applicable to cable lugs with one hole in the palm. | |
| Price Code : A | |
| MS IEC 61540 : 2003 | |
| Electrical accessories - Portable residual current devices without integral overcurrent protection for household and similar use (PRCDs) | |
| This Malaysian Standard applies to portable devices for household and similar uses [hereafter referred to as portable residual current devices (PRCDs)] consisting of a plug, a residual current device (RCD) and one or more socket-outlets or a provision for connection, functionally independent of, or functionally dependent on, line voltage. They do not incorporate overcurrent protection. They are intended for single-phase circuits for rated currents not exceeding 16 A for rated voltages not exceeding 130 V a. c. to earth. They are intended to provide protection against shock hazard in case of direct contact, in addition to the protection provided by the fixed installations for the circuit downstream. | |
| Price Code : V | |
| Wires | |
| MS 435 : 1976 | |
| Specification for wrought aluminium for electrical purposes wire. | |
| Specifies
requirements for aluminium round wire for electrical
conductors of diameters 0.4 mm up to and including 10 mm. |
|
| Price Code : B | |
| MS 528 : 1977 | |
| Specification for stranded wire ropes, fibre components : Characteristics and tests. | |
| Specifies
types of fibre, properties of yarns and methods of test
for water soluble acids, salt and extractable content. |
|
| Price Code : A | |
| MS 529 : 1977 | |
| Specification for stranded wire ropes for mine hoisting - impregnating compounds and lubricants - characteristics and tests. | |
| Specifies
properties and test methods for : (a) impregnating compounds for fibre main cores, fibre covers and fibre inserts; (b) lubricants used in manufacture; (c) service dressings. Notes on qualification and quality control tests are also specified. |
|
| Price Code : B | |
| MS 550 : 1978 | |
| Round steel wire for ropes. | |
| Covers
general requirements and test methods applicable to three
types general purpose round steel wire of diameters 0.19
m and 5 mm and two types of high duty wire of diameters
between 0.8 mm and 3.5 mm. |
|
| Price Code : C | |
| MS 551 : 1978 | |
| Specification for wire ropes for cranes, excavators and general engineering purposes. | |
| Specifies
material, manufacture, inspection, test and acceptance.
Appended are recommendations for the selection, use and
care of wire ropes, terminology and definitions. |
|
| Price Code : D | |
| MS 552 : 1978 | |
| Specification for steel wire ropes for electric lifts. | |
| Specifies
requirements on material, manufacture inspection testing
and acceptance for steel wire suspension and ancillary
ropes for electric lifts. |
|
| Price Code : B | |
| MS 754 : 1981 | |
| Specification for stranded wire ropes - Technical delivery requirements. | |
| Outlines
those properties which forms a basis for acceptance of
stranded wire ropes and their component part. |
|
| Price Code : B | |
| MS 796 : 1982 | |
| Specification for small wire ropes. | |
| For ropes
7mm and smaller. Specifies requirements on mechanical
properties, manufacture and acceptance. |
|
| Price Code : B | |
| MS 824 : 1983 | |
| Specification for thimbles for wire ropes. | |
| Specifies
materials and dimensions of ordinary reeving and solid
types thimbles. Also includes form and dimensions,
workmanship, finish and inspection. |
|
| Price Code : B | |
| MS 1092 : 1987 | |
| Specification for low carbon steel wire rods. | |
| Specifies
low carbon steel wire rods to be used for the manufacture
of iron wires, armoured cable wires, galvanized iron wire
strands, telegraph wires, etc. This standard does not
apply to wire rods for core wires of coated electrode. |
|
| Price Code : A | |
| MS 1093 : 1987 | |
| Specification for high carbon steel wire rods. | |
| Specifies
high carbon steel wire rods to be used for the
manufacture of high carbon steel wires, oil tempered
wires, high carbon steel wires for prestressed concrete,
galvanized steel wire strands, steel wire ropes etc. |
|
| Price Code : A | |
| MS 1237 : 1991 | |
| Specification for general purpose galvanized steel wire strand. | |
| This
Malaysian Standard specifies requirements for seven
tensile strength grades of galvanized steel wire strand
in sizes from 1.7 mm to 23.8 mm diameter, intended for a
variety of purposes including railway signalling strand. |
|
| Price Code : B | |
| MS 1238 : 1991 | |
| Specification for galvanized steel wire for aluminium conductors, steel-reinforced. | |
| This
Malaysian Standard specifies the requirements for
galvanized steel wire, as supplied by the wire
manufacture, for the manufacturer of aluminium
conductors, steel reinforced in accordance with MS 1198. |
|
| Price Code : A | |
| MS 1239 : 1991 | |
| Specification for galvanized low carbon steel wire for armouring cables. | |
| This
Malaysian Standard specifies requirements for galvanized
round low carbon steel wire, primarily for armouring of
land cables, in diameters ranging from 0.30 mm to 4.0 mm.
The nominal wire diameters given in table 1 are the
preferred sizes and are in the R 40 series in accordance
with BS 4391. The material used for the wire shall be the
wire rods conforming to MS 1092. |
|
| Price Code : A | |
| MS 1240 : 1991 | |
| Specification for galvanized steel wire for armouring submarines cables. | |
| This
Malaysian Standard specifies requirements for galvanized
round steel wire in diameters ranging from 2.12 mm to
8.50 mm for armouring submarine cables. The nominal wire
diameters specified in tables 1, 2 and 3 are the
preferred sizes, and are in the R 40 series or BS 4398. |
|
| Price Code : B | |
| MS IEC 60439-2 : 2002 | |
| Low-voltage switchgear and controlgear assemblies - Part 2: Particular requirements for busbar trunking systems (busways). | |
| This Malaysian Standard applies to busbar trunking systems (BTS) and their accessories for feeding and distributing electrical power in residential, retail, public, agriculture and industrial premises. It also applies to busbar trunking systems which are designed to incorporate communication and/or control systems or intended to supply luminaries through tap-off units but does not apply to supply track systems in accordance with IEC 60570. | |
| Price Code : D | |
Cables |
|
| MS 69 : 1995 | |
| Specification for conductors in insulated cables and cords (Second revision). | |
| This
Malaysian Standard specifies the nominal cross-sectional
areas and requirements, including numbers and sizes of
wire and resistance values, for conductors in electric
cables and cords of a wide range of types. These
conductors include solid and stranded copper and
aluminium conductors' 'in cables for fixed installations
and flexible copper conductors'. |
|
| Price Code : D | |
| MS 136 : 1995 | |
| Specification for PVC insulated cables (non-armoured) for electric power and lighting (Second revision). | |
| This
Malaysian Standard specifies requirements and dimensions
for non-armoured PVC-insulated cables for operation at
voltages up to and including 450V to earth and 760V
between conductors. |
|
| Price Code : D | |
| MS 137 : 1973 | |
| Specification for PVC insulated cables for switchgear and control gear wiring. | |
| Specifies
requirements for single-core cables, including flexible
cables used for the small wiring of switches, meters
relays and instrument panels of power switchgear.
Classifies cables into 2 types according to test
properties. Details on construction and overall
dimensions, electrical tests and measurement of
insulation thickness are given. |
|
| Price Code : B | |
| MS 138 : 1995 | |
| specification for PVC-insulated and sheath of electric cables (Second revision). | |
| This
Malaysian Standard specifies the physical and electrical
requirements for the types of PVC insulation and sheath
of electric cables given in Table 1. The relevant test
methods for verification of compliance are given either
in MS 1095 or in the appendices of this standard. This
standard shall supersede MS 138 :1987, 'PVC insulation
and sheath of electric cables'. |
|
| Price Code : A | |
| MS 140 : 1987 | |
| Specification for insulated flexible cords and cables (First revision). | |
| Specifies
requirements and dimensions for flexible cords and cables
for operation at voltages up to and including 450V earth
and 750V between conductors. |
|
| Price Code : F | |
| MS 274 : 1995 | |
| specification for PVC insulated cables for electricity supply (Second revision). | |
| This
Malaysian Standard specifies the requirement and
dimensions for PVC-insulated cables for operation at
nominal voltages up to and including 1900V to armour or
earth and 3300V between conductors. This standard covers
cables intended for general use where the combination of
the ambient temperature and temperatures rise due to the
loading current results in a conductor temperature not
exceeding 70C. |
|
| Price Code : E | |
| MS 276 : 1987 | |
| Specification for rubber insulation and sheath of electric cables (First revision). | |
| Covers
specification compositions, colour and requirements for
tensile strength and elongation at break, water
absorption, insulation resistance constant, tear
resistance, ozone resistance, oil resistance and
permittivity. |
|
| Price Code : B | |
| MS 278 : 1987 | |
| Specification for rubber insulated cables for electric power and lighting (First revision). | |
| Specifies
requirements for the construction electric properties,
mechanical properties and dimensions of non-armoured
rubber-insulated cables and flexible cables for operation
at voltages up to and including 451 V ac to earth and
750V ac between conductors. |
|
| Price Code : D | |
| MS 434 : 1976 | |
| Specification for wrought aluminium for electrical purposes solid conductors for insulated cables. | |
| Specifies
requirements for circular solid and 2- 3-, and 4- core
shaped solid conductors in a range of standard sizes from
16 mm squared up to and including 300 mm squared. |
|
| Price Code : B | |
| MS 766 : Part 1 : 1982 | |
| Low-frequency communication cables and wires with PVC insulation and PVC sheath : Part 1 : General tests and measuring methods. | |
| Establishes
uniform requirements for electrical, climatic and
mechanical properties and test methods. |
|
| Price Code : B | |
| MS 1095 : 1987 | |
| Method or test for insulation and sheaths of electric cables. | |
| Describes
methods of test used for testing extruded polymeric
insulation and sheaths of electric cables. |
|
| Price Code : H | |
| MS 1141 : 1989 | |
| Specification for portable cable reel for domestic and similar purposes. | |
| Applies to
cable reels for a.c. circuits only provided with
non-detachable flexible cable or cord and having a rated
voltage not exceeding 250 V intended for domestic and
similar purposes, either indoors or outdoors. Does not
apply to cable reeling devices incorporated in appliances
or to portable switchgear for buildings and similar
sites. |
|
| Price Code : E | |
| MS IEC 60183 : 2003 | |
| Guide to the selection of high-voltage cables | |
| This Malaysian Standard is identical with IEC 60183:1984 and its Amendment 1:1990. This Malaysian Standard gives guidance in the selection of the conductor size, insulation level and construction of cable to be used on three-phase alternating current systems operation at voltages exceeding 1 kV. | |
| Price Code : B | |
| MS IEC 60228 : 2001 | |
| Conductors of insulated cables | |
| Specifies the standardised nominal cross-sectional areas from 0.5 mm2 to 2 000 mm2; as well as numbers and diameters of wires and resistance values for conductors in electric cables and flexible cords. This standard does not apply to conductors for telecommunication purposes, and it applies to conductors of special design only when stated in the specification for the type of cable. | |
| Price Code : C | |
| MS IEC 60229 : 2001 | |
| Tests on cable oversheaths which have a special protective function and are applied by extrusion | |
| This
standard provides a range of standard tests which may be
required for protective coverings consisting of extruded
oversheaths when the coverings, in addition to protecting
underlying metallic layers against corrosion, are
required to fulfil special functions. The tests required
in this standard are only appropriate to particular
conditions and use and do not have to be implemented for
normal conditions and use. Guidance on their
implementation will be provided in the relevant cable
specification. |
|
| Price Code : A | |
| MS IEC 60287-1-2 : 2001 | |
| Electric cables - Calculation of the current rating - Part 1 : Current rating equations (100 % load factor) and calculation of losses - Section 2 : Sheath eddy current loss factors for two circuits in flat formation | |
| This section of IEC 60287-1 provides a method for calculating the eddy current losses in the metallic sheaths of single-core cables arranged as a three-phase double circuit in flat formation. The sheaths are bonded at one point or are cross-bonded so that there are no significant sheath circulating currents. | |
| Price Code : D | |
| MS IEC 60287-2-1 : 2001 | |
| Electric cables - Calculation of the current rating - Part 2 : Thermal resistance - Section 1 : Calculation of thermal resistance | |
| This section
of IEC 60287 is solely applicable to the conditions of
steady-state operation of cables at all alternating
voltages, and direct voltages up to 5 kV, buried directly
in the ground, in ducts in troughs or in steel pipes,
both with and without partial drying-out of the soil, as
well as cables in air. The term "steady state"
is intended to mean a continuous constant current (100 %
load factor) just sufficient to produce asymptotically
the maximum conductor temperature, the surrounding
ambient conditions being assumed constant. |
|
| Price Code : D | |
| MS IEC 60287-2-2 : 2001 | |
| Electric cables - Calculation of the current rating - Part 2 : Thermal resistance - Section 2 : A method for calculating reduction factors for groups of cables in free air, protected from solar radiation | |
| The method
described in this Malaysian Standard is applicable to any
type of cable and group running horizontally, provided
that the cables are of equal diameter and emit equal
losses. |
|
| Price Code : B | |
| MS IEC 60287-3-2 : 2003 | |
| Electric cables Calculation of the current rating Part 3: Sections on operating conditions Section 2: Economic optimization of power cable size | |
| This Malaysian Standard is identical with IEC 60287-3-2:1995 and its Amendment 1:1996. This Malaysian Standard deals solely with the economic choice of conductor size based on joule losses. Voltage dependent losses have not been considered. | |
| Price Code : D | |
| MS IEC 60331-11 : 2001 | |
| Tests for electric cables under fire conditions - Circuit integrity - Part 11 : Apparatus - Fire alone at a flame temperature of at least 750°C | |
| This part of
MS IEC 60331 specifies the test apparatus to be used for
testing cables required to maintain circuit integrity
when subject to fire alone where the test condition is
based upon a flame with a controlled heat output
corresponding to a temperature of at least 750°C. It
also provides in annex A the method of verification of
the burner and control system used for the test. |
|
| Price Code : B | |
| MS IEC 60331-21 : 2001 | |
| Tests for electric cables under fire conditions - Circuit integrity - Part 21 : Procedures and requirements - Cables of rated voltage up to and including 0.6/1.0 kV | |
| This part of
MS IEC 60331 specifies the test procedure and gives the
performance requirement, including a recommended flame
application time, for cables of rated voltage up to and
including 0.6/1.0 kV required to maintain circuit
integrity when subjected to fire under specified
conditions. It describes the means of sample preparation,
continuity checking arrangements, electrical testing
procedure, method of burning the cables and gives
requirements for evaluating test results. |
|
| Price Code : B | |
| MS IEC 60331-23 : 2001 | |
| Tests for electric cables under fire conditions - Circuit integrity - Part 23 : Procedures and requirements - Electric data cables | |
| This part of
MS IEC 60331 specifies the test procedure and gives the
performance requirement, including a recommended flame
application time, for electric data cables required to
maintain circuit integrity when subjected to fire under
specified conditions. It describes the means of sample
preparation, continuity checking arrangements, electrical
testing procedure, method of burning the cables and gives
requirements for evaluating test results. |
|
| Price Code : B | |
| MS IEC 60331-25 : 2001 | |
| Tests for electric cables under fire conditions - Circuit integrity - Part 25 : Procedures and requirements - Optical fibre cables | |
| This part of
MS IEC 60331 specifies the test procedure, and gives the
performance requirement, including a recommended flame
application time, for optical fibre cables required to
maintain circuit integrity when subjected to fire under
specified conditions. It describes the means of sample
preparation, continuity checking arrangements, optical
testing procedures, the method of burning the cables and
gives requirements for evaluating test results. |
|
| Price Code : A | |
| MS IEC 60332-1 : 2001 | |
| Tests on electric cables under fire conditions - Part 1 : Test on a single vertical insulated wire or cable | |
| Specifies a
method of test on a single vertical insulated wire or
cable under fire conditions and the requirements for
compliance. |
|
| Price Code : B | |
| MS IEC 60332-2 : 2001 | |
| Tests on electric cables under fire conditions - Part 2 : Test on a single small vertical insulated copper wire or cable | |
| Specifies a
method of testing a small insulated wire under fire
conditions when the method specified in MS IEC 60332-1 is
not suitable because some small conductors may melt
during the application of the flame. The range of
application recommended is for solid copper conductors
from 0.4 mm to 0.8 mm diameter and for stranded
conductors from 0.1 mm2 to 0.5 mm2
cross-section. This standard includes the requirement for
compliance. |
|
| Price Code : A | |
| MS IEC 60502-1 : 1998 | |
| Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um - 1,2 kV) up to 30 kV ((Um - 36 kV) - Part 1 : Cables for rated voltages of 1 kV (Um - 1,2 kV) and 3 kV (Um - 3,6 kV) | |
| This
Malaysian Standard is identical with IEC 60502-1 : 1997.
This standard specifies the construction, dimensions and
test requirements for power cables with extruded solid
insulation of rated voltages 1 kV and 3 kV for fixed
installations such as distribution networks or industrial
installations. Cables for special installation and
service conditions are not included, for example cables
for overhead networks, the mining industry, nuclear power
plants (in and around the containment area), submarine
use or shipboard application. The standard supersedes MS
IEC 502:1996, Extruded solid dielectric insulated power
cables for rated voltages from 1 kV up to 30 kV. |
|
| Price Code : F | |
| MS IEC 60502-2 : 1998 | |
| Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um - 1,2 kV) up to 30 kV ((Um - 36 kV) - Part 2 : Cables for rated voltages of 6 kV (Um - 7,2 kV) and 30 kV (Um - 36 kV) | |
| This
Malaysian Standard is identical with IEC 60502-2 : 1997.
This standard specifies the construction, dimensions and
test requirements for power cables with extruded solid
insulation from 6 kV and 30 kV for fixed installations
such as distribution networks or industrial
installations. Cables for special installation and
service conditions are not included, for example cables
for overhead networks, the mining industry, nuclear power
plants (in and around the containment area), submarine
use or shipboard application. The standard supersedes MS
IEC 502:1996, Extruded solid dielectric insulated power
cables for rated voltages from 1 kV up to 30 kV. |
|
| Price Code : G | |
| MS IEC 60502-4 : 1998 | |
| Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um - 1,2 kV) up to 30 kV ((Um - 36 kV) - Part 4 : Test requirements on accessories for cables with rated voltages from 6 kV (Um - 7,2 kV) and 30 kV (Um - 36 kV) | |
| This
Malaysian Standard is identical with IEC 60502-4 : 1997.
This standard specifies the test requirements for type
testing of accessories for power cables with rated
voltages from 6 kV up to 30kV. Accessories for particular
cables, such as aerial, submarine or ship cables are not
included. The standard supersedes MS IEC 502:1996,
Extruded solid dielectric insulated power cables for
rated voltages from 1 kV up to 30 kV. |
|
| Price Code : D | |
| MS IEC 60811-1-1 : 1997 | |
| Common test methods for insulating and sheathing materials of electric cables. Part 1: Methods for general application - Section 1: Measurement of thickness and overall dimensions - Tests for determining the mechanical properties. | |
| This
Malaysian Standard is a total adoption of IEC 811-1-1 :
1993. This standard specifies the test methods to be used
for testing polymeric insulating and sheathing materials
of electric cables for power distribution and
telecommunications including cables used on ships. |
|
| Price Code : C | |
| MS IEC 60811-1-2 : 1997 | |
| Common test methods for insulating and sheathing materials of electric cables. Part 1: Methods for general application - Section 2: Thermal ageing methods. | |
| This
standard specifies the test methods to be used for
testing polymeric insulating and sheathing materials of
electric cables for power distribution and
telecommunications including cables used on ships. This
Section Two of Part 1 gives the thermal ageing methods which apply to the most common types of insulating and sheathing compounds (elastometric, PVC, PE, PP etc.) |
|
| Price Code : C | |
| MS IEC 60811-1-3 : 1997 | |
| Common test methods for insulating and sheathing materials of electric cables. Part 1: Methods for general application - Section 3 : Method for determining the density - Water absorption tests - Shrinkage test | |
| This
standard specifies the test methods to be used for
testing polymeric insulating and sheathing materials of
electric cables for power distribution and
telecommunications including cables used on ships. This
Section Three of Part 1 gives the methods for the
determining the density, Water absorption tests,
Shrinkage test which apply to the most common types of
insulating and sheathing compounds (elestometric, PVC,
PE, PP etc) |
|
| Price Code : B | |
| MS IEC 60811-1-4 : 1997 | |
| Common test methods for insulating and sheathing materials of electric cables. Part 1: Methods for general application - Section 4 : Tests at low temperature. | |
| This
standard specifies the test methods to be used for
testing polymeric insulating and sheathing materials of
electric cables for power distribution and
telecommunications including cables used on ships. This
Section Four of Part 1 gives the methods for tests at low
temperature which apply to PVC and PE compounds. |
|
| Price Code : C | |
| MS IEC 60811-2-1 : 1997 | |
| Common test methods for insulating and sheathing materials of electric cables. Part 2: Methods specific to elastometric compounds - Section One : Ozone resistance test-Hot set test-Mineral oil immersion test. | |
| This
Malaysian Standard is a total adoption of IEC 811-2-1 :
1986. This standard specifies the test methods to be used
for testing polymeric insulating and sheathing material
of electric cables for power distribution and
telecommunications including cables used on ships. This
Section One of Part 2 gives the methods for the ozone
resistance test, hot set test and mineral oil immersion
test, which apply to elastomeric compounds. |
|
| Price Code : B | |
| MS IEC 60811-3-1 : 1997 | |
| Common test methods for insulating and sheathing materials of electric cables. Part 3: Methods specific to PVC compounds - Section One : Pressure test at high temperature - Tests for resistance to cracking. | |
| This
Malaysian Standard is a total adoption of IEC 811-3-1 :
1985. This standard specifies the test methods to be used
for testing polymeric insulating and sheathing materials
of electric cables for power distribution and
telecommunications including cables used on ships. This
Section One of Part 3 gives the methods for pressure test
at high temperature and for tests for resistance to
cracking, which apply to PVC compounds. This standard
includes Amendment 1 : 1994 to IEC 811-3-1 : 1985. |
|
| Price Code : C | |
| MS IEC 60811-3-2 : 1997 | |
| Common test methods for insulating and sheathing materials of electric cables. Part 3: Methods specific to PVC compounds - Section Two : Loss of mass test - thermal stability test. | |
| This
standard specifies the test methods to be used for
testing polymeric insulating and sheathing materials of
electric cables for power distribution and
telecommunications including cables used on ships. This
Section Two of Part 3 gives the methods for loss of mass
test and thermal stability test, which apply to PVC
compounds. This standard includes Amendment 1 : 1993 to
IEC 811-3-2 : 1985. |
|
| Price Code : C | |
| MS IEC 60811-4-1 : 1997 | |
| Common test methods for insulating and sheathing materials of electric cables. Part 4 : Methods specific to polyethylene and polypropylene compounds - Section One : Resistance to environmental stress cracking - Wrapping test after thermal ageing in air - Measurement of the melt flow index - Carbon black and/or mineral content measurement in PE. | |
| This
Malaysian Standard is a total adoption of IEC 811-4-1 :
1985. This standard specifies the test methods to be used
for testing polymeric insulating and sheathing materials
of electric cables for power distribution and
telecommunications including cables used on ships. This
Section One of Part 4 gives the methods for measurement
of the resistance to environmental stress cracking, for
wrapping test after thermal ageing in air, for
measurement of melt flow index and for measurement of
carbon black and/or mineral content, which apply to PE
and PP compounds, including cellular compounds and foam
skin for insulation. This standard includes Amendment 2 :
1993 to IEC 811-4-1 : 1985. |
|
| Price Code : C | |
| MS IEC 60811-4-2 : 1997 | |
| Common test methods for insulating and sheathing materials of electric cables. Part 5 : Methods specific to polyethylene and polypropylene compounds - Section Two : Elongation at break after pre-conditioning - Wrapping test after thermal ageng in air- Measurement of mass increase - Long - term stability test (Appendix A) - Test method for copper - Catalysed oxidative degradation (Appendix B) | |
| This
Malaysian Standard is a total adoption of IEC 811-4-2 :
1990. This standard specifies the test methods for
testing polymeric insulating and sheathing materials of
electric cables for power distribution and
telecommunications including cables used on ships. This
Section Two of Part 4 gives the methods for measurement
of elongation at break after pre-conditioning, for
wrapping test after pre-conditioning, for wrapping test
after thermal ageing in air, for measurement of mass
increase, for long-term stability test and for
measurement of copper-catalysed oxidative degradation,
which apply to polyolefin insulations. |
|
| Price Code : C | |
| MS IEC 60811-5-1 : 1997 | |
| Common test methods for insulating and sheathing materials of electric cables. Part 5 : Methods specific to filling compounds - Section One : Drop -point - Separation of oil - lower temperature brittleness - Total acid number- Absence of corrosive components- Permittivity at 23 °C D.C. Resistivity at 23°C and 100°C. | |
| This
Malaysian Standard is a total adoption of IEC 811-5-1 :
1990. This standard specifies the test methods for
filling compounds of electric cables used with
telecommunication equipment. This part includes
definitions, requirements and tests, covering all types
of RCCB's. This standard shall supersede MS 1139 : 1989. |
|
| Price Code : B | |
| MS IEC 60885-1 : 2003 | |
| Electrical
test methods for electric cables Part 1:
Electrical tests for cables, cords and wires for voltages
up to and 450/750 V. |
|
| This
Malaysian Standard is identical with IEC 60885-1:1987.
This Malaysian Standard specifies the electrical test
methods for testing wires, cords and cables where the
relevant cable standard does not prescribe a different
electrical test method. The electrical tests are only
applicable to: -unsheathed wires, cords and cables,;
-cores taken from complete sheathed cords and cables, all
having a maximum rated voltage up to and including
450/750 V. |
|
| Price Code : A | |
| MS IEC 60885-2 : 2003 | |
| Electrical test methods for electric cables Part 2: Partial discharge tests. | |
| This
Malaysian Standard is identical with IEC 60885-2:1987.
This Malaysian Standard specifies the test methods for
electrical cables. |
|
| Price Code : A | |
| MS IEC 60885-3 : 2003 | |
| Electrical test methods for electric cables Part 3: Test methods for partial discharge measurements on lengths of extruded power cables. | |
| This Malaysian Standard is identical with IEC 60885-3:1988. This Malaysian Standard specifies the essential requirements for partial discharge measurements on lengths of extruded power cable. | |
| Price Code : F | |
Components for electrical equipment |
|
Electrical and electromechanical components |
|
| MS 859 : Part 1 : 1991 | |
| Specification for electricity meters (electromechanical) : Part 1 : Class 0.5, 1 and 2 single-phase and polyphase, single rate and multi-rate watthour meters (First revision). | |
| This standard specifies the mechanical and electrical requirements and type tests, for single-phase and polyphase, single rate and multi-rate, induction type watthour meters of accuracy classes 0.5, 1 and 2, for the measurement of alternating current electrical active energy of a frequency in the range of 45 Hz to Hz, and having a voltage across the connection terminals not exceeding 600 V (line-to-line for meters for polyphase systems). | |
| Price Code : D | |
| MS 859 : Part 2 : 1989 | |
| Specification for electricity meters : Part 2 : Specification for class 3 var-hour meters. | |
| Specifies the mechanical and electrical requirements and type tests for single-phase and polyphase, single rate and multi-rate, var-hour (reactive volt-ampere-hour) meters of accuracy Class 3, for the measurement of alternating current electrical reactive energy of a frequency in the range 45 Hz to 65 Hz and having a voltage across connection terminals not exceeding 600 V (line to line for meters for polyphase systems) | |
| Price Code : B | |
| MS 859 : Part 3 : 1996 | |
| Specification for electricity meters : Part 3 : Specification for meters having class 1 electro-mechanical maximum demand indicators (First revision). | |
| This revised Malaysian Standard specifies the mechanical and electrical requirements and type tests for meters having maximum demand indicators of class 1. Such indicators are intended to operate as attachments. Coupled mechanically to watt-hour or var-hour meters and to indicate the maximum mean value of power (active or reactive) measured during successive meter may have any specified accuracy class. This standard shall supersede MS 859 : Part 3 : 1989. | |
| Price Code : B | |
Electrical accessories |
|
| MS 1144 : 1998 | |
| General requirements for electric accessories (First revision). | |
| This Malaysian Standard specifies requirements and tests to check the safety in normal use of electrical accessories which are not covered by other specific Malaysian Standards. This standard also covers 'plug-in' and other accessories in which electrical accessory component are incorporated, e.g. plug-pins, socket-contacts, switches. terminals, etc. | |
| Price Code : G | |
| MS IEC 60335-2-95 : 2003 | |
| Household and similar electrical appliances safety : Part 2-95 : Particular requirements for drives for vertically moving garage doors for residential use | |
| Price RM20 | |
| MS IEC 60335-2-97 : 2003 | |
| Household and similar electrical appliances-Safety-Part 2-97: Particular requirements for drives for rolling shutters, awnings, blinds and similar equipment | |
| This Malaysian Standard deals with the safety of electric drives for rolling equipment such as shutters, blinds and awnings, intended for household and similar purposes, their rated voltage being not more than 250 V for single-phase appliances and 480 V for other appliances. | |
| Price RM20 | |
Conduits for electrical purposes |
|
| MS 275 : Part 1 : 1975 | |
| Specification for steel conduits and fittings with metric threads or ISO form for electrical installations : Part 1 : Steel conduits, bends & couplers (internationally acceptable sizes). | |
| Covers classification, dimensions and tests. Closely agree with CEE Publication. | |
| Price Code : C | |
| MS 275 : Part 2 : 1975 | |
| Specification for steel conduits and fittings with metric threads of ISO form for electrical installations : Part 2 : Fittings and components (non-internationally acceptable sizes). | |
| Specifies classification, dimensions and tests for conduit fittings and components of sheet or malleable cast iron. In certain cases a wide choice of materials is given and indicated on relevant standard sheets. | |
| Price Code : D | |
| MS 1034 : 1986 | |
| Specification for rigid polyvinyl chloride conduit for underground telecommunication cables. | |
| Covers the requirements including materials and test methods to determine heat reversion, tensile, impact strength and resistance to acetone. | |
| Price Code : B | |
| MS 1534 : Part 1 : 2002 | |
| Specification for conduit systems for electrical installations : Part 1 : General requirements | |
| This standard specifies requirements and tests for conduit systems, including conduits and conduit fittings, for the protection and management of insulated conductors and/or cables in electrical installations or in communication systems up to 1 000 V a.c. and/or 1 500 V d.c.. This standard supersedes MS 67 : Part 1 : 1972 | |
| Price Code : D | |
| MS 1534 : Part 2 : Section 1 : 2002 | |
| Specification for conduit systems for electrical installations : Part 2 : Particular requirements : Section 1 : Rigid conduit systems | |
| This clause
of Part 1 is applicable, except as follows. Addition: This standard specifies the requirements for rigid conduit systems. Conduit systems which are used as an integral part of other equipment also have to be tested according to the relevant standard for that equipment. This standard supersedes MS 67 : Part 1 : 1972. |
|
| Price Code : B | |
| MS 1534 : Part 2 : Section 2 : 2003 | |
| Specification for conduit systems for electrical installations: Part 2: Particular requirements: Section 2: Pliable conduit systems | |
| This standard specifies requirements and tests for conduit systems, including conduits and conduit fittings, for the protection and management of insulated conductors and/or cables in electrical installations or in communication systems up to 1 000 V a.c. and/or 1 5000 V d.c. This Standard applies to metallic, non-metallic and composite conduit systems including threaded and non-threaded entries which terminate the system. This Standard does not apply to enclosures and connecting boxes which come within the scope of MS IEC 60670. This standard specifies the requirements for pliable conduit systems including self-recovering conduit systems. Conduit systems which are used as an integral part of other equipment also have to be tested according to the relevant standard for that equipment. | |
| Price Code : B | |
| MS 1534 : Part 2 : Section 3 : 2003 | |
| Specification for conduit systems for electrical installations: Part 2: Particular requirements: Section 3: Flexible conduit systems | |
| This standard specifies requirements and tests for conduit systems, including conduits and conduit fittings, for the protection and management of insulated conductors and/or cables in electrical installations or in communication systems up to 1 000 V a.c. and/or 1 5000 V d.c. This Standard applies to metallic, non-metallic and composite conduit systems including threaded and non-threaded entries which terminate the system. This Standard does not apply to enclosures and connecting boxes which come within the scope of MS IEC 60670. This standard specifies the requirements for flexible conduit systems. Conduit systems which are used as an integral part of other equipment also have to be tested according to the relevant standard for that equipment. | |
| Price Code : A | |
| MS 1534 : Part 2 : Section 4 : 2003 | |
| Specification for conduit systems for electrical installations: Part 2: Particular requirements: Section 4: Conduit systems buried underground | |
| This standard specifies requirements and tests for conduit systems, including conduits and conduit fittings, for the protection and management of insulated conductors and/or cables in electrical installations or in communication systems up to 1 000 V a.c. and/or 1 5000 V d.c. This Standard applies to metallic, non-metallic and composite conduit systems including threaded and non-threaded entries which terminate the system. This Standard does not apply to enclosures and connecting boxes which come within the scope of MS IEC 60670. This clause of Part 1 is applicable. This standard specifies requirements and tests for conduit systems buried underground including conduits and conduit fittings for the protection and management of insulated conductors and/or cables in electrical installations or in communication systems. This standard applies to metallic, non-metallic and composite systems including threaded and non-threaded entries which terminate the system. Conduit systems which are used as an integral part of other equipment shall also be tested according to the relevant specification for that equipment. | |
| Price Code : B | |
| MS IEC 60423 : 2002 | |
| Conduits for electrical purposes Outside diameters of conduits for electrical installations and threads for conduits and fittings | |
| This Malaysian Standard specifies outside diameters for conduits used in electrical installations and the dimensional requirements for threads used in associated fittings. | |
| Price Code : C | |
Plugs, socket outlets, couplers |
|
| MS 589 : Pt. 1 : 1997 | |
| Specification for 13A plugs, socket-outlets, adaptors and connection units : Part 1 : Specification for rewirable and non-rewirable 13A plugs (First revision) | |
| This Malaysian Standard specifies requirements for 13A fused plugs having insulating sleeves on line and neutral pins, for household, commercial and light industrial purposes, with particular reference to safety in normal use. The plugs are suitable for the connection of portable appliances, sound-vision equipment, luminaires, etc., in a.c. circuits only, operating at voltages not exceeding 250 V r.m.s at 50 Hz. This standard supersedes MS 589 : 1989. | |
| Price Code : G | |
| MS 589 : Pt. 2 : 1997 | |
| Specification for 13A plugs, socket-outlets, adaptors and connection units : Part 2 : Specification for 13A switched and unswitched socket-outlet (First revision) | |
| This Malaysian Standard specifies requirements for 13A switched and unswitched shuttered socket outlets for household, commercial and light industrial purposes, with particular reference to safety in normal use. The socket-outlets are suitable for the connection of portable appliances, sound-vision equipment, luminaires, etc., in a.c. circuits only, operating at voltages not exceeding 250 V r.m.s at 50 Hz using plugs in accordance with Part 1.This standard shall supersede MS 589 : 1989. | |
| Price Code : G | |
| MS 589 : Pt. 3 : 1998 | |
| Specification for 13A plugs, socket-outlets, adaptors and connection units : Part 3 : Specification for adaptors. | |
| This part of MS 589 specifies for requirements for adaptors having insulating sleeves on the line and neutral plug pins and suitable for use with sockets outlets complying with MS 589:Part 2, with particular reference to safety in normal use. Adaptors specified in this Standard are intended for household, commercial and light industrial purposes. The adaptors are suitable for the connection of potable appliances, sound-vision equipment, luminaires, etc., in a.c. circuits only operating at voltages not exceeding 250 V r.m.s. at 50Hz. | |
| Price Code : J | |
| MS 589 : Pt. 4 : 1997 | |
| Specification for 13A plugs, socket-outlets, adaptors and connection units : Part 4 : Specification for 13A fused connection units : Switched and unswitched | |
| This standard specifies requirements for 13A fused fixed connection units for household, commercial and light industrial purposes, with particular reference to safety in normal use. The connection units are suitable for the connection of appliances in a.c. circuits only, operating at voltages not exceeding 250 V r.m.s at 50 Hz. | |
| Price Code : D | |
| MS 1578 : 2003 | |
| Specification for flat non-rewirable two-pole plugs, 2.5 A, 250 V, with cord, for the connection of Class II Equipment for household and similar purposes | |
| This Malaysian Standard applies to flat non-rewirable two-pole plugs without earthing contact with a rated voltage of 250 V a.c. and a rated current of 2.5 A. They are supplied with a cord, for the connection of equipment of class II, for household and similar purposes, and having no special protection against ingress of water and intended for indoor use. Plugs complying with this standard are suitable for use at ambient temperature not normally exceeding 25 °C, but occasionally reaching 35 °C. This standard applicable to plug portions of adaptors or equipment, such as razors or lamps with rechargeable batteries, plug-in transformers, etc. as far as the standard reasonably applies. | |
| Price Code : C | |
| MS 1579 : 2003 | |
| Specification for portable 2 pin socket-outlets for Class II equipment for household and similar purposes | |
| This Malaysian Standard applies to portable 2 pin socket-outlets for a.c. only, without earthing contacts, with a rated voltage of 250 V and a rated current not exceeding 13 A, intended foe household and similar purposes. | |
| Price Code : E | |
| MS IEC 60320-1 : 2003 | |
| Appliance couplers for household and similar general purposes Part 1: General requirements | |
| This part of MS IEC 60320 is applicable to two-pole appliance couplers for a.c. only, with or without earthing contact, with a rated voltage not exceeding 250 V and a rated current not exceeding 16 A, for household and similar general purposes and intended for the connection of a supply cord to electrical appliances or other electrical equipment for 50 Hz or 60 Hz supply. NOTES: 1. Appliance inlets integrated or incorporated in appliances or other equipment are within the scope of this standard. The dimensional and general requirements of this standard apply to such inlets, but certain tests may not be relevant. 2. The requirements for connectors are based on the assumption that the temperature of the pins of the corresponding appliance inlets does not exceed 70 °C for connectors for cold conditions; 120 °C for connectors for hot conditions; 155 °C for connectors for very hot conditions 3. Appliance couplers complying with this standard are suitable for use at ambient temperatures not normally exceeding 25 °C, but occasionally reaching 35 °C. 4 Appliance couplers complying with the standard sheets in this standard are intended for the connection of equipment having no special protection against moisture. If appliance couplers are used with equipment which may be subject to spillage of liquid in normal use then protection against moisture is to be provided by the equipment. 5. Special constructions may be required - in locations where special conditions prevail, for example, as in ships, vehicles and the like: - in hazardous locations, for example, where explosions are liable to occur. | |
| Price Code : M | |
| MS IEC 60320-2-2 : 2003 | |
| Appliance couplers for household and similar general purposes Part 2-2: Interconnection couplers for household and similar equipment | |
| This clause of MS IEC 60320-1 is replaced as follows: This standard is applicable to two-pole interconnection couplers for a.c. only, with and without earthing contact, with a rated voltage not exceeding 250 V and a rated current not exceeding 16 A, for household and similar appliances and equipment and intended for the interconnection of the electrical supply to electrical appliances or equipment for 50 Hz or 60 Hz supply. Appliance outlets integrated in or incorporated in appliances or other equipment are within the scope of this standard. The dimensional and general requirements of this standard apply to such outlets, but certain tests may not be relevant. The requirements for plug connectors are based on the assumption that the temperature of the socket contacts of the corresponding appliance outlets does not exceed 65 °C (cold conditions). Interconnection couplers complying with the standard sheets in this standard are intended for the interconnection of appliances or equipment having no special protection against moisture; for the interconnection of other appliances or equipment and of an appliance or equipment which is subject to spillage of liquid in normal use, additional requirements are necessary. Special constructions may be required - in locations where special conditions prevail as, for example, in ships, vehicles and the like; - in hazardous locations, for example, where explosions are liable to occur. | |
| Price Code : E | |
Switches |
|
| MS 616 : Part 1 : 1998 | |
| Switches for household and similar fixed-electrical installations : Part 1: General requirements (First revision) | |
| This standard applies to manually operated general purpose switches for a.c. only with a rated voltage not exceeding 440 V and a rated current not exceeding 63A, intended for household and similar fixed-electrical installation, either indoors or outdoors. The rated current is limited to 16A maximum for switches provided with screwless terminals. | |
| Price Code : K | |
| MS 616 : Part 2 : Section 1 : 2000 | |
| Switches for household and similar fixed electrical installations : Part 2 : Particular requirements : Section 1 : Electronic switches | |
| Applies to electronic switches and to associated electronic extension units for household and similar fixed electrical installations either indoors or outdoors. It applies to electronic switches for the operation of lamp circuits and the control of the brightness of lamps (dimmers) as well as the control of the speed of motors (e.g. those used in ventilating fans) and for other purposes (e.g. heating installations), with a working voltage not exceeding 250 V a.c. and a rated current up to and including 16 A. | |
| Price Code : D | |
| MS 616 : Part 2 : Section 2 : 2000 | |
| Switches for household and similar fixed electrical installations : Part 2 : Particular requirements : Section 2 : Electromagnetic remote-control switches (RCS) | |
| Applies to electromagnetic remote-control switches (hereinafter referred to as RCS) with a rated voltage not exceeding 440 V and a rated current not exceeding 63 A, intended for household and similar fixed electrical installations, either indoors or outdoors. | |
| Price Code : B | |
| MS 616 : Part 2 : Section 3 : 2000 | |
| Switches for household and similar fixed electrical installations : Part 2 : Particular requirements : Section 3 : Time delay switches (TDS) | |
| Applies to time-delay switches (hereinafter referred to as TDS) with a rated voltage not exceeding 440 V and a rated current not exceeding 63 A, intended for household and similar fixed electrical installations, either indoors or outdoors, operated by hand and/or by remote control and which are provided with a mechanical, thermal, pneumatic, hydraulic or electrical operated time-delay device or with a device which combines any of them. | |
| Price Code : B | |
| MS 1039 : 1986 | |
| Specification for alternating current switches of rated voltage above one kilovolt | |
| Price Code : H | |
| MS 1577 : 2003 | |
| Specification for 15 A plugs and socket-outlets for domestic and similar purposes | |
| This Malaysian Standard specifies the requirements for 15 A rewirable plugs and switched or unswitched socket-outlets for use on a nominal supply voltage not exceeding 250 V a.c. single-phase 50 Hz. For switched socket-outlets which contain a switch connected between the current carrying contact(s) of the socket-outlets and the relevant supply terminal(s). In general, the provisions of this standard shall apply to plugs when wired with appropriate flexible cords or cables, and to socket-outlets installed. | |
| Price Code : C | |
| MS IEC 60669-1 : 2004 | |
| Switches for household and similar fixed electrical installation Part 1 : General requirements | |
| This part of IEC 60669 applies to manually operated general purpose switched, for a.c. only with a rated voltage not exceeding 440 V and a rated current not exceeding 63 A, intended for household and similar fixed-electrical installations, either indoors or outdoors. | |
| Price RM190 | |
| MS IEC 60669-2-1 : 2004 | |
| Switches for household and similar fixed electrical installations Part 2-1: Particular requirements Electronics switches | |
| This standard applied to electronic switches and associated electronic extension units for household and similar fixed electrical installations either indoors or outdoors. | |
| Price RM90 | |
| MS IEC 60669-2-2 : 2003 | |
| Switches for household and similar fixed electrical installation Part 2-2: Particular requirements Remote control switches (RCS) | |
| This standard applies to remote-control switches (hereinafter referred to as RCS). This standard applies to electromagnetic RCS with a rated voltage exceeding 440 V and a rated current not exceeding 63 A, and to electronic RCS with a rated voltage not exceeding250 V and a rated current not exceeding 16 A, intended for household and similar fixed electrical installations, either indoors or outdoors | |
| Price RM30 | |
| MS IEC 60669-2-3 : 2004 | |
| Switches for household and similar fixed electrical installations Part 2-3: Particular requirements Time-delay switches (TDS) | |
| This standard applies to time-delay switches (hereinafter referred to as TDS) with a rated voltage not exceeding 440 V and a rated current not exceeding 63 A, intended for household and similar fixed electrical installations, either indoors or outdoors, operated by hand and/or by remote control and which are provided with a mechanical, thermal, pneumatic, hydraulic or electrical operated time-delay device or with combines any of them. | |
| Price RM30 | |
Fuses and other overcurrent protection devices |
|
| MS 1428 : 1998 | |
| Specification for general purpose fuse links for domestic and similar purposes (primarily for use in plugs). | |
| This Malaysian Standard specifies dimensions and performance requirements for general purpose cartridge fuse links of current ratings not exceeding 13A for domestic and similar purposes. | |
| Price Code : C | |
| MS 1586 : Part 3 : 2003 | |
| Low-voltage fuses - Part 3: Supplementary requirements for fuses for use by unskilled persons (fuses mainly for household and similar applications). | |
| This Malaysian Standard applies to gG fuses for use by unskilled persons for domestic and similar applications with rated currents not exceeding 100 A and rated voltages not exceeding 500 V a. c. Additional specific requirements are given in IEC Publication 269-3-1. | |
| Price Code : C | |
| MS IEC 60269-1 : 2003 | |
| Low-voltage fuses Part 1: General requirements | |
| This Malaysian Standard is applicable to fuses incorporating enclosed current-limiting use fuse links with related breaking capacities of not less than 6 kA, intended for protecting power-frequency a. c. circuits of nominal voltages not exceeding 1 000 V or d. c. circuits or normal voltages not exceeding 1 500 V. | |
| Price Code : N | |
| MS IEC 60269-2-1 : 2003 | |
| Low voltage fuses-Part 2-1: Supplementary requirements for use by authorised person (Fuses mainly for industrial application)-Section I to IV: Examples of types of standardized fuses | |
| The following additional requirements apply to fuses with fuse-links having blade contacts intended to be replaced by means of a device, for example replacement handle, which complies with the dimensions specified in figures 1(I*) and 2(I*).Such fuses have rated currents up to and including 1250A and rated voltages up to and including AC 690 V or DC 440V. | |
| Price RM260 | |
| MS IEC 60269-3-1 : 2003 | |
| Low-voltage fuses Part 3-1: Supplementary requirements for fuses for use by unskilled persons (fuses mainly for household and similar applications) Sections I to IV | |
| This Malaysian Standard is divided into four sections, each dealing with a specific example of standardised fuses: Section I: D-type fuses (fuse links and fuse-holders) Section II: Cylindrical fuses Type A Type B Type C Section III: Pin-type fuses Section IV: Cylindrical fuse-links (primarily used in plugs). | |
| Price Code : T | |
| MS IEC 60269-4 : 2003 | |
| Low-voltage fuses - Part 4: Supplementary requirements for fuse-links for the protection of semiconductor devices | |
| These supplementary requirements apply to fuse-links for application in equipment containing semiconductor devices for circuits of rated voltages up to 1000 V a.c. or circuits of nominal voltages up to 1500 V d.c. and also, in so far as they are applicable, for circuits of higher nominal voltages. | |
| Price RM60 | |
| MS IEC 60898 : 1998 | |
| Electrical accessories - Circuit- Breakers for overcurrent protection for household and similar installations (MCB'S) | |
| This standard applies to a.c. air-break circuit-breakers for operation at 50 Hz or 60 Hz, having a rated voltage not exceeding 440 V (between phases), a rated current not exceeding 125 A and a rated short-circuit capacity not exceeding 25,000 A.This standard supersedes MS 1370 : 1995. | |
| Price Code : L | |
| MS IEC 60898-1: 2003 | |
| Electrical accessories circuit-breakers for overcurrent protection for household and similar installations - Part 1: Circuit-breakers for a.c. operation | |
| This part of MS IEC 60898 applies to a.c. air-break circuit-breakers for operation at 50 Hz or 60 Hz, having a rated voltage not exceeding 440 V (between phases), a rated current not exceeding 125 A and a rated short-circuit capacity not exceeding 25 000 A. | |
| Price RM250 | |
| MS IEC 60898-2 : 2003 | |
| Circuit-breakers for overcurrent protection for household and similar installations - Part 2: Circuit-breakers for a.c. and d.c. operation | |
| Price RM40 | |
| MS IEC 60947-2 : 2000 | |
| Low-voltage switchgear and controlgear - Part 2 : Circuit-breakers | |
| Applies to circuit-breakers, the main contacts of which are intended to be connected to circuits, the rated voltage of which does not exceed 1 000 V a.c. or 1 500 V d.c.; it also contains additional requirements for integrally fused circuit-breakers. This standard is identical with IEC 60947-2 : 1998. | |
| Price Code : P | |
| MS IEC 60947-3 : 2000 | |
| Low-voltage switchgear and controlgear - Part 3 : Switches, disconnectors, switch-disconnectors and fuse-combination units | |
| Applies to switches, disconnectors, switch-disconnectors and fuse-combination units to be used in distribution circuits and motor circuits of which the rated voltage does not exceed 1 000 V a.c. or 1 500 V. d.c. This standard is identical with IEC 60947-3 : 1999. | |
| Price Code : F | |
| MS IEC 61008-1 : 2003 | |
| Residul current operated circuit-breakers without integral overcurrent protection for household and similar uses(RCCBs) Part 1: General rules | |
| This Malaysian Standard applies to residual current operated circuit-breakers functionally independent of, or functionally dependent on, line voltage, for household and similar uses, not incorporating overcurrent protection (hereafter referred to as RCCBs), for rated voltages not exceeding 440 V a.c. and rated currents not exceeding 125 A, intended principally for protection against shock-hazard. | |
| Price RM140 | |
| MS IEC 61008-2-1 : 2003 | |
| Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) Part 2-1: Applicability of the general rules to RCCBs functionally independent of line voltage. | |
| This Part 2-1 supplements or modifies the corresponding clauses in MS IEC 61008-1 to cover its applicability to RCCB's functionally independent of line voltage. This clause of Part 1 is applicable, except as follows: Replace the first paragraph by the following: This Malaysian Standard applies to RCCB's functionally independent of line voltage, for household and similar uses, not incorporating overcurrent protection, for rated voltages not exceeding 440 V a.c. and rated currents not exceeding 125 A, intended principally for protection against electric shock hazard. | |
| Price RM10 | |
| MS IEC 61008-2-2 : 2003 | |
| Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) Part 2-2: Applicability of the general rules to RCCBs functionally dependent on line voltage. | |
| This Part 2-2 supplements or modifies the corresponding clauses in MS IEC 61008-1 to cover its applicability to RCCB's functionally dependent on line voltage. This clause of part 1 is applicable | |
| Price RM110 | |
| MS IEC 61009-1 : 2003 | |
| Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBOs) | |
| Price RM280 | |
| MS IEC 61009-2-1 : 2003 | |
| Residual current operated circuit-breakers with integral overcurrent protection for household and similar | |
| Price RM10 | |
| MS IEC 61009-2-2 : 2003 | |
| Residual current operated circuit-Breakers with integral overcurrent protection for household and similar uses (RCBOs). Part 2-2: Applicability of the general rules to RCBOs functionally dependent on line voltage | |
| Price RM10 | |
29.120.60 |
|
| MS IEC 60439-5 : 2004 | |
| Low-voltage switchgear and controlgear assemblies Part 5 : Particular requirements for assemblies Part 5: Particular requirements for assemblies intended to be installed outdoors in public places Cables distribution cabinets (CDCs) for power distribution in networks | |
| This standard gives supplementary requirements for cable distribution cabinets (CDCs), which are stationary, type-tested assemblies (TTA) for outdoor installation in places which are exposed to the public, but where only skilled persons have access for their use. They are for use in public three-phase systems. | |
| Price RM120 | |
Other electrical accessories |
|
| MS IEC 60670 : 2002 | |
| General requirements for enclosures for accessories for household and similar fixed electrical installations | |
| This Malaysian Standard applies to enclosures or parts of enclosures for accessories with a rated voltage not exceeding 440 V, intended for household or similar fixed electrical installations, either indoors and outdoors. | |
| Price Code : D | |
Switchgear and controlgear |
|
| MS 1445 : Pt. 1 : 1998 | |
| Low voltage switchgear and controlgear asemblies Part 1 : Type-tested and partially type-tested assemblies. | |
| This Malaysian Standard applies to low-voltage switchgear and controlgear assemblies (type-tested assemblies (TTA) and partially type-tested assemblies (PTTA), the rated voltage of which does not exceed 1000 V a.c. at frequencies not exceeding 1000 Hz, or 1500 V d.c. | |
| Price Code : L | |
| MS 1445 : Pt. 3 : 1998 | |
| Low voltage switchgear and controlgear asemblies Part 3 : Particular requirements for low-voltage switchgear and controlgear assemblies intended to be installed in places where unskilled persons have access for their - Distribution boards | |
| This Malaysian Standard gives requirements for enclosed distribution boards (DBU), which are stationary, type-tested assemblies (TTA) for indoor use, containing protective devices and intended for use either in domestic (household) applications or in other places where unskilled persons have access for their use. Control and/or signalling devices may also be included. They are for use on a.c., with a nominal voltage to earth not exceeding 300 V. The outgoing circuits contain short-circuit protective devices, each having a rated current not exceeding 125 A with a total incoming load current not exceeding 250 A. | |
| Price Code : K | |
| MS IEC 60529 : 2002 | |
| Degrees of protection provided by enclosures (IP Code) | |
| This Malaysian Standard applies to the classification of degrees of protection provided by enclosures for electrical equipment with a rated voltage not exceeding 72.5 kV. | |
| Price Code : E | |
Low voltage switchgear and controlgear |
|
| MS 948 : 1984 | |
| Specification for factory-built assemblies of switchgear and controlgear. | |
| Applies to low voltage switchgear and controlgear where rated voltage does not exceed 100V a.c. and at frequencies not exceeding 1000Hz, or 1200V d.c. Included too are those designed for use under special service conditions e.g. in ships, in rail vehicles, for hoisting equipment or in explosive atmospheres, and for domestic applications. | |
| Price Code : F | |
| MS IEC 60439-1 : 2003 | |
| Low-voltage switchgear and controlgear assemblies - Part 1: Type-tested and partially type-tested assemblies | |
| This Malaysian Standard applies to low-voltage switchgear and controlgear ASSEMBLIES (type-tested ASSEMBLIES (TTA) and partially type-tested ASSEMBLIES (PTTA)), the rated voltage of which does not exceed 1 000 V a.c. at frequencies not exceeding 1 000 Hz, or 1 500 V d.c. | |
| Price RM100 | |
| MS IEC 60439-3 : 2003 | |
| Low-voltage switchgear and controlgear assemblies - Part 3: Particular requirements for low_voltage switchgear and controlgear assemblies intended to be installed in places where unskilled persons have access for their use-Distribution boards | |
| Replace the second note by: This standard gives supplementary requirements for such enclosed distribution boards (DBU), which are stationary, type tested assemblies (TTA) for indoor use, containing protective devices and intended for use either in domestic (household) applications or in other places where unskilled persons have access for their use. Control and/or signalling devices may also be included. They are for use on a.c., with a nominal voltage to earth not exceeding 300 V. The outgoing circuits contain short-circuit protective devices, each having a rated current not exceeding 125 A with a total incoming load current not exceeding 250 A. | |
| Price RM20 | |
| MS IEC 60947-1 : 2004 | |
| Low-voltage switchgear and controlgear Part 1 : General rules | |
| This standard applies, when required by the relevant product standard, to switchgear and controlgear hereinafter referred to as "equipment" and intended to be connected to circuits, the rated voltage of which does not exceed 1 000 V a.c. or 1 5000 V d.c. | |
| Price RM340 | |
| MS IEC 60947-4-1 : 1996 | |
| Specification for low-voltage switchgear and controlgear : Part 4 : Contactors and motor-starters : Section 1 : Electromechanical contactors and motor-starters. | |
| This Malaysian Standard applies to the types of equipment listed in sub-clauses 1.1.1 (A.C and d.c contactors) and 1.1.2 (A.C motor-starters), hereinafter whose main contactors are intended to be connected to circuits the rated voltage of which does not exceed 1000 V a.c or 1500 V d.c.Starters and/or contactors dealt with in this standard are not normally designed to interrupt short-circuit currents. Therefore, suitable short-circuit protection shall form part of the installation but not necessarily of the contactor or the starter. | |
| Price Code : M | |
| MS IEC 60662 : 2002 | |
| High-pressure sodium vapour lamps - Section One : General | |
| This Malaysian Standard specifies the characteristics of high-pressure sodium vapour lamps necessary to ensure interchangeability and safety together with test conditions and procedures. The recommendations relate only to type testing. The standard specifies the lamp dimensions, electrical characteristics for lamp starting and operation together with information for ballast, ignitor and luminaire design purpose | |
| Price Code : N | |
Lamps and related equipment |
|
| MS IEC 60922 : 1995 | |
| Specification for ballasts for discharge lamps (excluding tubular fluorescent lamps). | |
| This Malaysian Standard specifies safety requirements for ballasts for discharge lamps such as high-pressure mercury vapour, low-pressure sodium vapour, high-pressure sodium vapour and metal halide lamps. Section one specifies general requirements and section two specifies thermal and mechanical requirements. The standard covers inductive-type ballasts for use on a.c supplies up to 1000 V at 50Hz or 60Hz associated with discharge lamps, having rated wattages, dimensions and characteristics as specified in the relevant IEC lamp standards according to IEC Publications 188, 192 and 662. | |
| Price Code : G | |
| MS IEC 60923 : 1995 | |
| Specification for performance requirements for ballasts for discharge lamps (excluding tubular fluorescent lamps). | |
| This Malaysian Standard specifies performance requirements for ballasts for discharge lamps such as high-pressure mercury vapour, low-pressure sodium vapour, high-pressure sodium vapour and metal halide lamps. Each section details specific requirements for a particular type of ballast. The standard covers inductive type ballasts for use on a.c supplies up to 1000V at 50Hz or 60Hz associated with discharge lamps, having rated wattage, dimensions and characteristics as specified in the relevant IEC lamp standards. | |
| Price Code : D | |
| MS IEC 60928 : 1995 | |
| Specification for a.c supplied electronic ballasts for tubular fluorescent lamps-general and safety requirements. | |
| This Malaysian Standard specifies general and safety requirements for electronic ballasts for use on a.c supplies up to 1000V at 50Hz or 60Hz with operating frequencies deviating from the supply frequency, associated with tubular fluorescent lamps as specified in IEC Publication 81 and other tubular fluorescent lamps for high-frequency operation. | |
| Price Code : E | |
| MS IEC 60929 : 1995 | |
| Specification for a.c supplied electronic ballasts for tubular fluorescent lamps-performance requirements. | |
| This Malaysian Standard specifies performance requirements for electronic ballasts for use on a.c supplies up to 1000V at 50Hz or 60Hz with operating frequencies deviating from the supply frequency, associated with tubular fluorescent lamps as specified in IEC 81 and 901 and other tubular fluorescent lamps for high-frequency operation. | |
| Price Code : D | |
| MS IEC 60983 : 2002 | |
| Miniatures lamps : Section 1 : General | |
| This
Malaysian Standard specifies requirements for miniature
halogen and non-halogen lamps with a nominal voltage up
to 30 V and a nominal wattage up to 25 W. It covers: - lamps to be used in road vehicles not subject to regulation and which therefore are not included in IEC 809 (section 2); - lamps for electric torches (section 3); - lamps for miners caplights (section 4). Aircraft lamps are standardized in IEC 434. This standard specifies dimensional, electrical and photometric requirements as well as requirements concerning life and mechanical strength |
|
| Price Code : E | |
Lamps in general |
|
| MS IEC 60399 : 2003 | |
| Standard sheets for barrel thread E14 and E27 lampholders with shade holder ring | |
| This Malaysian Standard is identical with IEC 60399:2002. This Malaysian Standard dives the limit dimensions of thread for metal or plastics and ceramic lamp holders with shade holder rings made of metal or plastics. | |
| Price Code : A | |
| MS IEC 60598-2-9 : 2001 | |
| Luminaires : Part 2 : Particular requirements - Section 9 - Photo and film luminaires (non-professional) | |
| This section of Part 2 of MS IEC Publication 60598 specifies requirements for photo and film luminaires (non-professional) for use with tungsten filament lamps on supply voltages not exceeding 250 V. | |
| Price Code : C | |
| MS IEC 60809 : 2001 | |
| Filament lamps for road vehicles - Dimensional, electrical and luminous requirements : Section 1 : General | |
| This Malaysian Standard covers filament lamps to be used in headlamps, fog-lamps and signalling lamps for road vehicles and specifies the technical requirements with methods of test and basic interchangeability (dimensional, electrical and luminous). It applies to those filament lamps which may be the subject of legislation. | |
| Price Code : N | |
| MS IEC 60810 : 2001 | |
| Lamps for road vehicles - Performance requirements : Section 1 : General | |
| This standard is one of a series of IEC standards for filament lamps to be used in head-lamps, fog-lamps and signaling lamps of road vehicles. It specifies performance requirements and test methods for the measurement of performance characteristics such as life, lumen maintenance, torsion strength, glass bulb strength and vibration resistance; moreover, information on temperature limits, maximum filament lamp outlines and maximum tolerable voltage surges is given for the guidance for lighting and electrical equipment design. | |
| Price Code : D | |
| MS IEC 60926 : 2001 | |
| Auxiliaries for lamps - Starting devices (Other than glow starters) - General and safety requirements - Section 1 : General | |
| This standard specifies general and safety requirements for starting devices (starters and ignitors) for tubular fluorescent and other discharge lamps for use on a.c. supplies up to 1 000 V at 50 Hz or 60 Hz which produce starting pulses not greater than 100 kV and which are used in combination with lamps and ballasts covered in IEC 60081, IEC 60188, IEC 60192, IEC 60662, IEC 60920 and IEC 60922. | |
| Price Code : D | |
| MS IEC 61046 : 2001 | |
| D.C. or A.C. supplied electronic step-down convertors for filament lamps - General and safety requirements - Section 1 : General requirements | |
| This Malaysian Standard specifies general and safety requirements for electronic step-down convertors for use on d.c. supplies up to 250 V or a.c. supplies up to 1 000 V at 50 Hz or 60 Hz and rated output voltage less or equals to 50 V r.m.s. at a frequency deviating from the supply frequency or less or equals to 50 (2 V unsmoothed d.c. between conductors or between any conductor and earth, associated with tungsten-halogen lamps as specified in IEC 60357 and other filament lamps. | |
| Price Code : F | |
| MS IEC 61047 : 2001 | |
| D.C. or A.C. supplied electronic step-down convertors for filament lamps - Performance requirements | |
| This Malaysian Standard specifies performance requirements for electronic step-down convertors for use on d.c. supplies up to 250 V and a.c. supplies up to 1 000 V at 50 Hz or 60 Hz with operating frequencies deviating from the supply frequency, associated with tungsten halogen lamps as specified in IEC 357 and other filament lamps. | |
| Price Code : C | |
| MS IEC 61126 : 2001 | |
| Procedure for use in the preparation of maximum lamp outlines - Section 1 : General | |
| This Malaysian Standard deals with the maximum lamp outline drawings and with the procedure to establish and apply them. It details step-by-step procedures which can be used to produce consistent, accurate but simplified drawings which can be called "maximum lamp outlines". The object of this standard is to provide guidelines for the preparation of maximum lamp outlines for those specific bulb shapes and caps noted. It is primarily for the use of the lamp standardizing committees. | |
| Price Code : F | |
| MS IEC 61228 : 2003 | |
| Method of measuring and specifying the UV-radiation of ultraviolet lamps used for sun-tanning | |
| This Malaysian Standard is identical with IEC 61228:1993 and its Amendment 1:1996. This Malaysian Standard specifies a method of measuring, evaluating and specifying the ultraviolet radiation of lamps which are used in skin treatment appliances for household and similar use, mainly for sun-tanning purposes. | |
| Price Code : B | |
Lamp caps and holders |
|
| MS 769 : 1982 | |
| Specification for bayonet lamp-caps lampholders and B.C adaptors (lampholder plugs). | |
| Definitions, dimensional and performance requirements and test methods provided. Parts intended use on a nominal voltage nor exceeding 250V. | |
| Price Code : E | |
| MS IEC 60155 : 1996 | |
| Glow-starters for fluorescent lamps. | |
| This
Malaysian Standard specifies interchangeable
glow-starters used with preheat type fluorescent lamps.
Hereafter called "starters". - Section 1 specifies the general and safety requirements with which starters shall comply; - Section 2 specifies the performance with Amendment. |
|
| Price Code : D | |
| MS IEC 60238 : 1999 | |
| Edison screw lampholders | |
| Applies to lampholders with Edison thread E14, E27 and E20, designed for connection to the supply of lamps and semi-luminaires only. Also applies to switched-lampholders for use in a.c. circuits only, where the working voltage does not exceed 250 V r.m.s. and to lampholders with Edison thread E5 designed for connection to the supply mains of series connected lamps, with a working voltage not exceeding 25 V, to be used indoors, and to lampholders with Edison thread E10 designed for connection to the supply mains of series connected lamps, with a working voltage not exceeding 60 V, to be used indoors or outdoors. It also applies to lampholders E10 for building-in, for the connection of single lamps to the supply. These lampholders are not intended for retail sale. This standard is identical with IEC 60238 : 1998. | |
| Price Code : H | |
| MS IEC 60360 : 1999 | |
| Standard method of measurement of lamp cap temperature rise | |
| Describes
the standard method of measurement of lamp cap
temperature rise which is to be used when testing
tungsten filament or discharge lamps for compliance with
the limits. Temperature-rise limits for particular lamp
types are, for example, listed in IEC 60432. It also
covers the method of test and the specifications for test
lampholders for lamps fitted with various sizes of ES and
BC caps. This method has been used widely for
incandescent lamps but its application is not limited to
that kind of lamp. This standard is identical with IEC
60360 : 1998. |
|
| Price Code : B | |
| MS IEC 60838-1 : 1999 | |
| Miscellaneous lampholders : Part 1 : General requirements and tests | |
| Applies to
lampholders of miscellaneous types intended for
building-in (To be used with general purpose lamps,
projection lamps, floodlighting lamps and street-lighting
lamps with caps as listed in Annex A0 and the methods of
test to be used in determining the safe use of lamps in
lampholders. Requirements for lampholders for tubular
fluorescent lamps, Edison screw lampholders and bayonet
lampholders are covered by separate standards. This
standard is identical with IEC 60838-1 : 1997. |
|
| Price Code : D | |
| MS IEC 60838-2-1 : 1999 | |
| Miscellaneous lampholders - Part 2 : Particular requirements - Section 1 : Lampholders S14 | |
| Applies to
lampholders S14 intended for building-in as well as for
independent lampholders for use with linear incandescent
lamps for general lighting service (GLS). Independent
lampholders are also tested as luminaires. This standard
is identical with IEC 60838-2-1 : 1994. |
|
| Price Code : B | |
| MS IEC 60400 : 1999 | |
| Lampholders for tubular fluorescent lamps and starterholders | |
| States the
technical and dimensional requirements for lampholders
for tubular fluorescent lamps and for starterholders, and
the methods of test to be used in determining the safety
and the fit of the lamps in the lampholders and the
starters in the starterholders. This standard is
identical with IEC 60400 : 1991 and its Amendment 1 :
1997. |
|
| Price Code : K | |
| MS IEC 61049 : 1999 | |
| Capacitors for use in tubular fluorescent and other discharge lamp circuits performance requirements | |
| States the
requirements for both self-healing and non-self-healing
continuous rated a.c. capacitors of up to and including
2.5 kvar, and not less than 0.1 mF,
having a rated voltage not exceeding 1,000 V, which are
intended for use in discharge lamp circuits operating at
50 Hz or 60 Hz and at altitudes up to 3,000 m. It also
covers capacitors intended for connection in shunt or in
series with the lamp circuit or an effective combination
of these and only those impregnated or unimpregnated
capacitors, having a dielectric of paper, plastic film or
a combination of both, either metallized or with metal
foil electrodes. This standard is identical with IEC
61049 : 1991. |
|
| Price Code : B | |
| MS IEC 61167 : 1999 | |
| Metal halide lamps | |
| Specifies
the methods of test to be used for determining the
characteristics of metal halide lamps, both single-ended
and double-ended, operated on a.c. mains, 50 Hz or 60 Hz,
with ballasts satisfying the requirements of IEC 923.
These requirements relate only to type testing. The
standard also specifies lamp dimensions, electrical
characteristics for lamp starting and operation together
with information for ballast, ignitor and luminaire
design and colour characteristics. This standard is
identical with IEC 61167 : 1992 and its Amendment 3 :
1998. |
|
| Price Code : D | |
Incandescent lamps |
|||||||||
| MS ISO 6570 : 2003 | |||||||||
| Electrical supply track systems for luminaires | |||||||||
| This
Malaysian standard applies to stack systems with two or
more poles for the connection of luminaires to the
electrical supply, either of rated voltage not exceeding
440 V between poles with provision for earthing (class I)
and a rated current not exceeding 16 A per conductor, or
of a rated SELV not exceeding 25 V without provision for
earthing (class III) and rated current not exceeding 25 A
per conductor. The track systems may also provide for the
mechanical support of the luminaires. It applies to track
systems designed for ordinary interior use for mounting
on, or flush with, or suspended from walls and ceilings.
These track systems are not intended for locations where
special conditions prevail as in ships, vehicles and the
like and in hazardous locations, for example, where
explosions are liable to occur. This standard shall be
read in conjunction with the sections of IEC 60598-1 to
which reference is made. |
|||||||||
| Price Code : D | |||||||||
| MS IEC 60064 : 1999 | |||||||||
| Tungsten filament lamps for domestic and similar general lighting purposes performance requirements | |||||||||
| Applies to
tungsten filament incandescent lamps for general lighting
service (GLS) which comply with the safety requirements
in IEC 432-1 and having: - rated wattage of 25 W to 200 W, inclusive; - rated voltage 100 V 250 V, including marked voltage range not exceeding ( 2.5 % of the mean voltage1); - bulbs of the A or PS shapes; - bulbs with clear, frosted or equivalently coated finishes, or white finishes; - caps B22d, E26 or E27. Specific lamp types are covered in section 8. This standard also states the performance requirements for lamps, including test methods and means of confirming compliance with the requirements. This standard is identical with IEC 60064 : 1993. |
|||||||||
| Price Code : K | |||||||||
| MS IEC 60357 : 2003 | |||||||||
| Tungsten halogen lamps (non-vehicle) | |||||||||
| This
Malaysian Standard specifies dimensions and
characteristics of tungsten halogen lamps. The standard
has been divided into sections according to the following
lamp applications: -PROJECTION -PHOTOGRAPHIC (including studio) -FLOODLIGHTING -SPECIAL PURPOSE -GENERAL PURPOSE -STAGE LIGHTING Lamps for automobile, aircraft and similar applications are not covered by this standard. NOTE. Projection lamps include those used for cinematograph and still projection applications. The specific requirements for tubular low-pressure tungsten halogen lamps are given in Clause 9. The requirements for lamp caps are given in IEC Publication 61-1. For the purpose of this standard the following voltage designations apply:
|
|||||||||
| Price RM110 | |||||||||
| MS IEC 60432-1 : 1996 | |||||||||
| Safety specifications for incandescent lamps : Part 1 : Tungsten filament lamps for domestic and similar general lighting purposes | |||||||||
| This
Malaysian Standard specifies the safety and
interchangeability requirements of tungsten filament
incandescent lamps for general lighting service, having a
rated wattage up to and including 200W and a rated
voltage from 50V to 250V inclusive - with Amendment No.
1. |
|||||||||
| Price Code : D | |||||||||
| MS IEC 60432-2 : 1996 | |||||||||
| Safety specifications for incandescent lamps : Part 2 : Tungsten halogen lamps for domestic and similar general lighting purposes | |||||||||
| This
Malaysian Standard specifies the safety and the related
interchangeability requirements of tungsten halogen lamps
for general lighting service. It covers those tungsten
halogen lamps that are used as direct replacements for
conventional tungsten filament lamps as well as new
tungsten halogen lamps. The safety and interchangeability requirements are treated by this standard. These tungsten halogen lamps the rated wattage up to and including 250W, rated voltage of 50V to 250V inclusive; outer envelopes with various finishes and bulb shapes. |
|||||||||
| Price Code : C | |||||||||
| MS IEC 60630 : 2003 | |||||||||
| Maximum lamp outlines for incandescent lamps | |||||||||
| This Malaysian Standard is identical wit IEC 60630:2001. This Malaysian Standard specifies requirements for maximum lamp outlines for incandescent lamps (including tungsten-halogen lamps). | |||||||||
| Price Code : E | |||||||||
| MS IEC 61549 : 2003 | |||||||||
| Miscellaneous lamps | |||||||||
| This Malaysian Standard specifies lamps or information relevant to lamps not covered elsewhere in the scope of existing IEC standards. | |||||||||
| Price Code : B | |||||||||
Fluorescent lamps. Discharge lamps |
|
| MS 141 : Part 1 : 1993 | |
| Specification for ballasts for tubular fluorescent lamps : Part 1 : General and safety requirements (First revision). | |
| This
Malaysian Standard specifies general and safety
requirements for ballasts excluding resistance types for
use on a.c. supplies up to 1000 V at 50 Hz, associated
with tubular fluorescent lamps with preheated cathodes
operated with or without a starter or starting device and
having rated wattage, dimensions and characteristics as
specified in IEC Publications 81 and 901. It applies to
complete ballasts and their component parts such as
resistors, transformers and capacitors. |
|
| Price Code : B | |
| MS 141 : Part 2 : 1993 | |
| Specification for ballasts for tubular fluorescent lamps : Part 2 : Performance requirements | |
| This
Malaysian Standard specifies performance requirements for
ballasts excluding resistance types for use on a.c.
supplies up to 1000 V at 50 Hz or 60 Hz, associated with
tubular fluorescent lamps with pre-heated cathodes
operated with or without a starter or starting device and
having rated wattages, dimensions and characteristics as
specified in IEC Publications 81 and 901. It applies to
complete ballasts and their component parts such as
resistors, transformers and capacitors. |
|
| Price Code : C Amendment 1 : 1997 | |
| MS 279 : 1983 | |
| Specification for capacitors for use in tubular fluorescent, high-pressure mercury and low-pressure sodium vapour discharge lamp circuits (First revision). | |
| Specifies
requirements for both self-heating and non-self-heating
capacitors of up to and including 2.5 Kvar. with
capacitance of not less than 0.1 F and having rated
voltage not exceeding 1Kv. Covers only impregnated or
unimpregnated capacitors having a dielectric of paper,
plastic film or combination of both, either metallized or
with metal foil electrode. Does not include
radio-interference suppressor capacitors. |
|
| Price Code : C | |
| MS IEC 60081 : 1997 | |
| Tubular fluorescent lamps for general lighting service | |
| This
Malaysian Standard is a total adoption of IEC 81:1984.
This standard covers a range of tubular fluorescent lamps
for general lighting service which are operated on a.c
mains. Lamps of the following types are included: 1) Lamps with pre-heated cathodes operated with the use of a starter; 2) Lamps with pre-heated cathodes operated without the use of a starter; 3) Lamps with pre-heated cathodes operated with or without the use of a starter; 4) Lamps with non-pre--heated cathodes operated without the use of a starter. The standard shall supersede MS 63 : 1972. |
|
| Price Code : XC | |
| MS IEC 60927 : 2003 | |
| Auxiliaries for lamps Starting devices (other than glow starters) Performance requirements | |
| This
Malaysian Standard is identical with IEC 60927:2000. This
Malaysian Standard specifies general performance
requirements for starting devices (starters and ignitors)
for tubular fluorescent and other discharge lamps for use
on a.c supplies up to 1 000 V at 50 Hz or 60 Hz which
produce starting pulses not greater than 5 kV. |
|
| Price Code : F | |
| MS IEC 61048 : 1999 | |
| Capacitors for use in tubular fluorescent and other discharge lamp circuits general and safety requirements | |
| States the
requirements for both self-healing and non-self-healing
continuously rated a.c. capacitors of up to and including
2.5 kvar, and not less than 0.1 mF,
having a rated voltage not exceeding 1,000 V, which are
intended for use in discharge lamp circuits* operating at
50 Hz or 60 Hz and at altitudes up to 3,000 m. It also
covers capacitors intended for connection in shunt or in
series with the lamp circuit or an effective combination
of these and only those impregnated or unimpregnated
capacitors, having a dielectric of paper, plastic film or
a combination of both, either metallized or with metal
foil electrodes. This standard is identical with IEC
61048 : 1991 and its Amendment 1 : 1995 and Amendment 2 :
1999. |
|
| Price Code : F | |
| MS IEC 61050 : 2001 | |
| Transformers for tubular discharge lamps having a no-load output voltage exceeding 1 000 V (generally called neon-transformers) - General and safety requirements - Section 1 : General requirements | |
| This
Malaysian Standard is applicable to independent and
built-in single-phase transformers with separate input
and output windings, for use on a.c. supply up to 1 000 V
at 50 Hz or 60 Hz, to supply and stabilize cold cathode
tubular lamps (or assemblies of such lamps) having a
no-load rated output voltage exceeding 1 000 V but not
exceeding 10 000 V (see notes 1 and 2) and intended for
lighting and for electric advertising signs, light
signals and similar purposes. |
|
| Price Code : E | |
| MS IEC 61195 : 2001 | |
| Double-capped fluorescent lamps - Safety specifications | |
| This
Malaysian Standard specifies the safety requirements for
double-capped fluorescent lamps for general lighting
purposes of all groups having Fa6, Fa8, G5, G13, 2G13,
R17d and W4, 3X8, 5d caps. It also specifies the method a
manufacturer should use to show compliance with the
requirements of this standard on the basis of whole
production appraisal in association with his test records
on finished products. This method can also be applied for
certification purposes. Details of a batch test procedure
which can be used to make limited assessment of batches
are also given in this standard. |
|
| Price Code : C | |
| MS IEC 61199 : 2001 | |
| Single-capped fluorescent lamps - Safety specifications | |
| This
Malaysian Standard specifies the safety requirements for
single-capped fluorescent lamps for general lighting
purposes of all groups having 2G7, 2GX7, GR8, 2G10, G10q,
GR10q, GX10q, GY10q, 2G11, G23, GX23, G24, GX24 and GX32
caps. It also specifies the method a manufacturer should
use to show compliance with the requirements of this
standard on the basis of whole production appraisal in
association with his test records on finished products.
This method can also be applied for certification
purposes. Details of a batch test procedure which can be
used to make limited assessment of batches are also given
in this standard. |
|
| Price Code : C | |
Luminaires |
|
| MS 619 : Part 2 : Sec. 2.6 : 1983 | |
| Specification for electric luminaires (lighting fittings) : Part 2 : Detail requirements : Section 2.6 : Electrical supply track systems for luminaires. | |
| Specifies for luminaire track systems with two or more poles, with provision for earthing, with a rated voltage not exceeding 250 V a.c. to earth at a frequency not exceeding 100 Hz and a rated current not exceeding 32 A per conductor, intended for the distribution of a supply for luminaires. | |
| Price Code : B | |
| MS 619 : Part 102 : Sec. 102.22 : 1985 | |
| Specification for luminaires for emergency lighting. | |
| This Provisional Malaysian Standard specifies requirements for emergency lighting luminaires for use with tungsten filament, tubular fluorescent and other discharge lamps on emergency power supplies not exceeding 1000 V. It is to be read in conjunction with those sections of IEC 598-1 (1979)* Part 1 to which reference is made.This Provisional Malaysian Standard does not cover 'explosion proof' luminaires for emergency lighting, (see IEC Publication 79 : Electrical apparatus for explosive gas atmospheres) and does not cover the effects of non-emergency voltage reductions on luminaires incorporating high pressure discharge lamps.NOTE. Some emergency lighting luminaires are designed for operation on normal power supplies during non-emergency periods. | |
| Price Code : B | |
| MS 983 : 2000 | |
| Specification for 'KELUAR' signs (Internally illuminated) (Second revision) | |
| Relates to internally illuminated box type KELUAR signs which are constructed for surface mounting; or capable of being recessed into a wall; or designed to be rigidly suspended from suitable brackets or fixings. The standard also relates to KELUAR signs which are incorporated in fascias associated with KELUAR doorways. This standard supersedes MS 983 : 1991. | |
| Price Code : B | |
| MS IEC 60192 : 2003 | |
| Low pressure sodium vapour lamps Performance specifications. | |
| This Malaysian Standard is identical with IEC 60192:2001. This Malaysian Standard specifies the methods of test to be used for determining the characteristics of low pressure sodium vapour lamps of the integral type, both U-shaped and linear, operating on a.c mains 50 Hz or 60 Hz. | |
| Price Code : C | |
| MS IEC 60570-2-1 : 2003 | |
| Electrical supply track systems for luminaires Part 2-1: Mixed supply system Classes I and III. | |
| This Malaysian standard applies to mixed supply track systems for connecting both class I and class III luminaires simultaneously, but in different track openings to the electrical supply, with two or more poles with a maximum nominal voltage of 440 V between poles (live conductors), maximum nominal frequency of 60 Hz and a maximum nominal current per conductor of 16 A for a class I sector and 25 A for a class III sector. It applies to track systems designed for ordinary interior use for mounting on, suspended from walls and ceilings. These track systems are not intended for locations where special conditions prevail as in ships, vehicles and the like and in hazardous locations, for example, where explosions are liable to occur. | |
| Price Code : B | |
| MS IEC 60598-1 : 2003 | |
| Luminaires - Part 1: General requirements and tests (First revision). | |
| This Malaysian Standard is identical with IEC 60598-1:1999. This Malaysian Standard specifies the general requirements for the classification and marking of luminaires and for their mechanical and electrical construction, together with related tests. This Malaysian Standard is applicable to luminaires for use with tungsten filaments, tubular fluorescent and other discharge lamps on supply voltages not exceeding 1 000 V. This Malaysian Standard cancels and replaces MS IEC 598-1:1997. | |
| Price Code : E | |
| MS IEC 60598-2-1 : 1997 | |
| Luminaires-Part 2 : Particular requirements - Section One - Fixed general purpose luminaires. | |
| This part of the standard specifies requirements for fixed general purpose luminaires for use with tungsten filament, tubular fluorescent and other discharge lamps on supply voltages not exceeding 1,000 V. It is to be read in conjunction with those sections of Part 1 to which reference is made. This standard includes Amendment 1:1987 to IEC 598-2-1:1979. This standard supersedes MS 619:Pt. 2:Sec. 2.2:1983. | |
| Price Code : B | |
| MS IEC 60598-2-2 : 1998 | |
| Luminaires-Part 2 : Particular requirements - Section Two - Recessed luminaires. | |
| This standard specifies the requirements for recessed luminaires for use with tungsten filament, tubular fluorescent and other discharge lamps on supply voltages not exceeding 1,000 V. this section does not apply to air-handling or liquid-cooled luminaires. It is to be read in conjunction with those sections of Part 1 to which reference is made. | |
| Price Code : B | |
| MS IEC 60598-2-3 : 1997 | |
| Luminaires-Part 2 : Particular requirements - Section Three - Luminaires for road and street lighting. | |
| This part of the standard specifies requirements for luminaires for road and street lighting for use with tungsten filament, tubular fluorescent and other discharge lamps on supply voltages not exceeding 1,000 V. It is to be read in conjunction with those sections of Part 1 to which reference is made. This standard supersedes MS 619 : Pt. 2 : Sec. 2.7 : 1983. | |
| Price Code : B | |
| MS IEC 60598-2-4 : 2003 | |
| Luminaires - Part 2: Particular requirements - Section 4: Portable general purpose luminaires (First revision). | |
| This Malaysian Standard specifies the requirements for portable general purpose luminaires, other than handlamps, for use with tungsten filaments, tubular fluorescent and other discharge lamps on supply voltages not exceeding 250 V. This Malaysian Standard cancels and replaces MS IEC 598-2-4:1997. | |
| Price Code : A | |
| MS IEC 60598-2-5 : 1999 | |
| Luminaires : Part 2-5 : Particular requirements - Floodlights | |
| Specifies requirements for floodlights for use with tungsten filament, tubular fluorescent and other discharge lamps on supply voltages not exceeding 1 000 V. It is to be read in conjunction with those sections of IEC 60598-1 to which reference is made. This standard is identical with CEI/IEC 60598-2-5 : 1998 and it supersedes MS 619 : Part 2 : Sec. 2.5 : 1982. | |
| Price Code : B | |
| MS IEC 60598-2-6 : 2003 | |
| Luminaires Part 2: Particular requirements Section 6: Luminaires with built-in transformers for filament lamps | |
| This section
of MS IEC 60598-2 specifies requirements for luminaire
with built-in transformers for filament lamps, with
supply voltages and output voltages not exceeding: - 1 000 V for class I and class II luminaires and - 250 V for class 0 luminaires. It is to be read in conjunction with those sections of IEC 598-1 to which reference is made. This section does not apply to class III luminaires. It is not necessary to use Safety extra low voltage" (SELV) transformers to comply with the requirements of this section. However, such transformers may satisfy the functional requirements of this section. |
|
| Price Code : B | |
| MS IEC 60598-2-7 : 2003 | |
| Luminaires Part 2: Particular requirements Section 7: Portable luminaires for garden use | |
| This section of Part 2 of MS IEC 60598 specifies requirements for portable pedestal luminaires for use in places such as gardens and for portable luminaires for use in places such as flower beds, for use with tungsten filament, tubular fluorescent and other discharge lamps on supply voltages not exceeding 250 V. It is to be read in conjunction with those sections of Part 1 to which reference is made. | |
| Price Code : B | |
| MS IEC 60598-2-8 : 1998 | |
| Luminaires-Part 2 : Particular requirements - Section Eight - Handlamps. | |
| This standard specifies the requirements for handlamps and similar portable luminaires which are held in the hand when used, for use with tungsten filament and tubular fluorescent lamps on supply voltages not exceeding 250 V. It is to be read in conjunction with those sections of Part 1 to which reference is made. The standard also incorporates Amendment 2 :1990 to IEC 598-2-8 :1981. This standard supersedes MS 619 : Pt. 2 : Sect. 2.3 : 1983. | |
| Price Code : C | |
| MS IEC 60598-2-10 : 1998 | |
| Luminaires-Part 2 : Particular requirements - Section Ten - Portable child-appealing luminaires. | |
| This standard specifies the requirements for portable child-appealing luminaires for use with tungsten filament lamps on supply voltages not exceeding 24 V (SELV). It is to be read in conjunction with those sections of Part 1 to which reference is made. The standard also incorporates Amendment 1:1990 to IEC 598-2-10 : 1987. | |
| Price Code : A | |
| MS IEC 60598-2-17 : 2003 | |
| Luminaires Part 2: Particular requirements Section 17: Luminaires for stage lighting, television and film studios (outdoor and indoor). | |
| This section of Part 2 of MS IEC 60598 specifies requirements for stage, television and film studio luminaires (including spot and floodlighting projectors), for use with tungsten filament, tubular fluorescent and other discharge lamps on supply voltages not exceeding 1000 V. It is to be read in conjunction with those sections of Part 1 to which reference is made. Note. A hanger (stirrup) is a part of the luminaire. Supporting devices such as tripods, telescopic booms and suspensions are not parts of the luminaire. Where applicable, ballasts are built into or mounted separately from the luminaires. | |
| Price Code : B | |
| MS IEC 60598-2-19 : 2003 | |
| Luminaires Part 2: Particular requirements Section 19: Air-handling luminaries (Safety requirements). | |
| This Malaysian Standard is identical with IEC 60598-2-19:1981 and its Amendment 2:1997. This Malaysian Standard specifies the safety requirements for air-handling luminaires for use with a ventilation space (plenum), for use with tubular flourescent lamps on supply voltage not exceeding 1 000 V. | |
| Price Code : B | |
| MS IEC 60598-2-18 : 1998 | |
| Luminaires-Part 2 : Particular requirements - Section 18 - Luminaires for swimming pools and similar applications. | |
| This standard specifies the requirements for fixed luminaires intended for use in water, or in contact with water, in for example, the basins of swimming pools, fountains, paddling pools, and garden pools, for use with tungsten filament, tubular fluorescent and other discharge lamps on supply voltages not exceeding 1000V. This section does not cover luminaires not in contact with water (e.g. mounted behind a glass panel which is separate from the luminaires) or hand-held or portable luminaires. | |
| Price Code : B | |
| MS IEC 60598-2-20 : 1998 | |
| Luminaires-Part 2 : Particular requirements - Section 20 - Lighting chains. | |
| This Malaysian Standard is identical the requirements for lighting chains fitted with series or parallel connected incandescent lamps for use either indoors or outdoors on supply voltages not exceeding 250 V. | |
| Price Code : B | |
| MS IEC 60598-2-23 : 2003 | |
| Luminaires Part 2: Particular requirements Section 23: Extra low voltage lighting systems for filament lamps. | |
| This Malaysian Standard is identical with IEC 60598-2-23:2001. This Malaysian Standard specifies requirements for extra low voltage systems for filament lamps intended for ordinary use on supply voltages not exceeding 1 000 V. | |
| Price Code : B | |
| MS IEC 60598-2-25 : 2001 | |
| Luminaires for use in clinical areas of hospitals and health care buildings | |
| This section of MS IEC 60598-2 details specific requirements for luminaires for use with tungsten filament, fluorescent and other discharge lamps on supply voltages not exceeding 1 000 V for use in clinical areas in which medical treatment, examination and medical care takes place in hospitals and health care buildings. | |
| Price Code : C | |
| MS IEC 60682 : 2003 | |
| Standard method of measuring the pinch temperature of quartz-tungsten-halogen lamps | |
| This Malaysian Standard is identical with IEC 60682:1980 and its Amendment 1:1987. This Malaysian Standard specifies details of the type of thermocouple to be used to measure the pinch temperature of quartz-tungsten-halogen amps, the methods of preparation of the lamp and thermocouple, and the measurement to be made. | |
| Price Code : C | |
| MS IEC 60901 : 2003 | |
| Single-capped fluorescent lamps Performance specifications | |
| This Malaysian Standard is identical with IEC 60901:1996. This Malaysian Standard specifies the performance requirements for single-capped fluorescent lamps for general lighting service. | |
| Price Code : E | |
Other standards related to lamps |
|
| MS IEC 60188 : 1999 | |
| High-pressure mercury vapour lamps | |
| States the methods of test to be used for determining the characteristics of high-pressure mercury vapour lamps with or without a red correcting fluorescent coating operating on a.c. mains with a ballast satisfying the requirements of IEC 262 : Ballasts for High Pressure Mercury Vapour lamps. These requirements relate only to type testing. Details of maximum lamp outlines are also included for guidance in luminaire design. This standard is identical with IEC 60188 : 1974. | |
| Price Code : D | |
| MS IEC 60925 : 2003 | |
| DC supplied electronic ballasts for tubular fluorescent lamps - Performance requirements | |
| Section one - General performance requirements. This standard specifies general performance requirements for electronic ballasts for use on d.c. supplies having rated voltages not exceeding 250 V, associated with fluorescent,lamps. Complying wit 60081. It shall be read in conjunction with lEC 60924. Performance requirements for electronic ballasts for general, public transport and aircraft lighting are specified in Sections Two, Three and Four of this standard. | |
| Price RM30 | |
| MS IEC 60634 : 1999 | |
| Heat test source (H.T.S.) lamps for carrying out heating tests on luminaires | |
| Specifies requirements for heat test source (H.T.S.) lamps used for carrying out those thermal tests of IEC 60598 which primarily check the influence of heat conducted through the lamp cap as well as of convection. For a description of the origin and philosophy of this standard see Annex A. Where H.T.S. lamps are not available, an alternative heat test source (A.H.T.S.) lamp may be used. This standard is identical with IEC 60634 : 1993. | |
| Price Code : B | |
| MS IEC 61347-1 : 2003 | |
| Lamp controlgear - Part 1: General and safety requirements | |
| This part of MS IEC 61347 specifies general and safety requirements for lamp controlgear for use on d.c. supplies up to 250 V and/or a.c. supplies up to 1 000 V at 50 Hz or 60 Hz. This standard also covers lamp control gear for lamps which are not yet standardized. Tests dealt with in this standard are type tests. Requirements for testing individual lamp control gear during production are not included. Requirements for semi-luminaires are given in lEC 60598. In addition to the requirements given in this standard, annex B sets out general and safety requirements applicable to thermally protected lamp controlgear. Annex C sets out additional general and safety requirements as they apply to electronic lamp controlgear with means of protection against overheating. | |
| Price RM70 | |
| MS IEC 61347-2-1 : 2003 | |
| Lamp controlgear - Part 2-1: Particular requirements for starting devices (other than glow starters) | |
| This part of MS lEC 61347 specifies particular safety requirements for starting devices (starters other than glow starters and ignitors) for fluorescent and other discharge lamps for use on a.c. supplies up to 1 000 V at 50 Hz or 60 Hz which produce starting pulses not greater than 100 kV and which are used in combination with lamps and ballasts covered in lEC 60081, lEC 60188, lEC 60192, lEC 60662, lEC 60901, lEC 61167, lEC 61195, lEC 61199, lEC 61347-2-8 and . lEC 61347-2-9. It does not apply to glow starters or starting devices which are incorporated in discharge lamps or which are manually operated. Preheat transformers for fluorescent lamps are covered by lEC 61347-2-8. | |
| Price RM30 | |
| MS IEC 61347-2-2 : 2003 | |
| Lamp controlgear - Part 2-2: Particular requirements for d.c. or a.c. supplied electronic step-down convertors for filament lamps | |
| This part of (lEC 61347 specifies particular safety requirements for electronic step-down convertors for use on d.c. supplies up to 250 V or a.c.. supplies up to 1 000 V at 50 Hz or 60 Hz and rated output voltage =50 V r.m.s. at a frequency deviating from the supply frequency or =50 V unsmoothed d.c. between conductors or between any conductor and earth, associated with tungsten-halogen lamps as specified in lEC 60357 and other filament lamps. | |
| Price RM40 | |
| MS IEC 61347-2-3 : 2003 | |
| Lamp controlgear - Part 2-3: Particular requirements for a.c. supplied electronic ballasts for fluorescent lamps | |
| This part of MS IEC 61347 specifies particular safety requirements for electronic ballasts for use on a.c. supplies up to 1 000 V at 50 Hz or 60 Hz with operating frequencies deviating from the supply frequency, associated with fluorescent lamps as specified in lEC 60081 and ,lEC 60901, and other fluorescent lamps for high-frequency operation. Particular requirements for electronic ballasts with means of protection against overheating are given in annex C. Particular requirements for a.c./ d.c. supplied electronic ballasts for maintained emergency lighting are given in annex J. Performance requirements are the subject of lEC 60929. | |
| Price RM30 | |
| MS IEC 61347-2-4 : 2003 | |
| Lamp controlgear - Part 2-4: Particular requirements for d.c. supplied electronic ballasts for general lighting | |
| This part of MS IEC 61347 specifies particular safety requirements for d.c. supplied electronic ballasts intended for operation from transient and surge-free power sources, operated directly from batteries without charging equipment as used in leisure equipment, for example, caravans, etc. | |
| Price RM20 | |
| MS IEC 61347-2-5 : 2003 | |
| Lamp controlgear - Part 2-5: Particular requirements for d.c. supplied electronic ballasts for public transport lighting | |
| This part of lEC 61347 specifies particular safety requirements for d.c. supplied electronic ballasts intended for operation from power sources likely to have attendant transients and surges, for example, for road and railway vehicles, tramcars, and craft used for public transport. Performance requirements are the subject of lEC 60925. | |
| Price RM30 | |
| MS IEC 61347-2-6 : 2003 | |
| Lamp controlgear - Part 2-6: Particular requirements for d.c. supplied electronic ballasts for aircraft lighting | |
| This part of MS IEC 61347 specifies particular safety requirements for d.c. supplied electronic ballasts intended for operation from power sources likely to have attendant transients and surges such as in aircraft. Performance requirements are the subject of lEC 60925. | |
| Price RM20 | |
| MS IEC 61347-2-7 : 2003 | |
| Lamp controlgear - Part 2-7 : Particular 'requirements for d.c. supplied electronic ballasts for emergency lighting. | |
| This part of IEC 61347 specifies particular safety requirements for d.c. supplied electronic ballasts for maintained and I)on-maintained emergency lighting purposes. | |
| Price RM20 | |
| MS IEC 61347-2-8 : 2003 | |
| Lamp controlgear - Part 2-8 : Particular requirements for ballasts for fluorescent lamps | |
| This part of MS IEC 61347 specifies safety requirements for ballasts, excluding resistance types, for use on a.c. supplies up to 1 000 V at 50 Hz or 60 Hz, associated with fluorescent lamps with or without pre-heated cathodes operated with or without a starter or starting device and having rated wattages, dimensions and characteristics as specified in IEC 60081 and 60901. | |
| Price RM30 | |
| MS IEC 61347-2-9 : 2003 | |
| Lamp controlgear - Part 2-9 : Particular requirements for ballasts for discharge lamps . (excluding fluorescent lamps) | |
| This part of IEC 61347 specifies particular safety requirements for ballasts for discharge lamps uch as high-pressure mercury vapour, low-pressure sodium vapour, high-pressure sodium vapour and metal halide lamps. The standard covers inductive-type ballasts for use on a.c. supplies up to 1 000 V at 50 Hz or 60 Hz, associated with discharge lamps, having rated wattages, dimensions and characteristics as specified in lEC 60188, lEC 60192 and lEC 60662. | |
| Price RM30 | |
| MS IEC 61347-2-10 : 2003 | |
| Lamp controlgear - Part 2-10 : Particular requirements for electronic invertors and convertors for high-frequency operation of cold start tubular discharge lamps (neon tubes) | |
| This part of MS IEC 61347 specifies particular requirements for electronic invertors and convertors for high-frequency operation of tubular cold-cathode discharge lamps used in signs and luminous-discharge tube installations and operating with an output voltage exceeding 1 000 v but not exceeding 10 000 V for direct connection to supply voltages not exceeding 1 000 V at 50 Hz or 60 Hz or 1 000 V d.c. | |
| Price RM30 | |
Rotating machinery |
|
Generating sets |
|
| MS 1403 : 1996 | |
| Electricity generating sets - Portable (up to 5kW). | |
| This Malaysian Standard specifies requirements for self-contained transportable electricity generating sets (hereinafter referred to as 'generating sets') driven by internal combustion engines and intended to provide an independent 50Hz a.c. supply of low voltage, single-phase at 240V. They may be portable or transportable. | |
| Price Code : D | |
Transformers. Reactors |
|
| MS 768 : 1982 | |
| General rules for power transformers (not exceeding 1 KVA rating) for electronic equipment. | |
| Covers definitions, design, construction and electrical performance for high phase power transformers with iron cones. | |
| Price Code : A | |
| MS 935 : 1984 | |
| Code of practice for loading guide for oil-immersed transformers. | |
| Establishes the permissible loading, under certain defined conditions, for the guidance of users and to help planners in choosing the rated power required for new installations. | |
| Price Code : E | |
| MS 1202 : 1991 | |
| Specification for current transformers. | |
| This Malaysian Standard specifies the requirements for current transformers suitable for frequencies of 15 Hz to 100 Hz and intended for use with electrical measuring instruments and electrical protective devices such as are covered, in general, by the following: MS 859, MS 925, BS 90, BS 142 and BS 3950. It also covers transformers for operating circuit-break trip coils. | |
| Price Code : F | |
| MS 1700 : 1998 | |
| Isolating transformers and safety isolating transformers - requirements | |
| This Malaysian Standard is identical with EN 60742 : 1989. This standard specifies the requirements for stationary or portable single-phase or polyphase, air-cooled isolating and safety isolating transformers. This standard shall supersede MS 936 : 1984. | |
| Price RM130 | |
| MS IEC 60335-2-29 : 2003 | |
| Household and similar electrical appliances safety - Part 2-29: Particular requirements for battery chargers | |
| This Malaysian Standard deals with the safety of electric battery chargers for household and similar use having an output at safety extra-low voltage, their rated voltage being not more than 250 V. | |
| Price RM40 | |
| MS EN 60742 : 1998 | |
| Isolating transformers and safety isolating transformers - requirements | |
| This Malaysian Standard is identical with EN 60742 : 1989. This standard specifies the requirements for stationary or portable single-phase or polyphase, air-cooled isolating and safety isolating transformers. This standard shall supersede MS 936 : 1984. | |
| Price Code : N | |
Rectifiers. Converters. Stabilized power supply |
|
| MS IEC 61204 : 1996 | |
| Low-voltage power supply devices, d.c. output - Performance characteristic and safety requirements. | |
| This
Malaysian Standard describes a method for specifying
requirements for low-voltage power supply devices
(including switching types) providing d.c. output (s) up
to 200 V d.c. at power level of up to 30 kW, operating
from a.c. or d.c. source voltages of up to 600 V. The
devices are for use within class 1 equipment or
free-standing operation when used with adequate
electrical and mechanical protection. This standard is
intended to cover all types of a.c. or d.c. driven units
with any number of outputs including power supply devices
used in military, industrial, telecommunications and
commercial applications. Special considerations apply for
medical applications and toys. |
|
| Price Code : D | |
| MS IEC 60335-2-29 : 1996 | |
| Safety of household and similar electrical appliances : Part 2 : Particular requirements for battery chargers. | |
| This
Malaysian Standard is a total adoption of IEC 335-2-29.
This part of the standard deal with the safety of battery
chargers for household and similar use having an output
at safety extra-low voltage, their rated voltage being
not more than 250V. Battery chargers not intended for
normal household use, but which nevertheless may be a
source of danger to the public, such as battery chargers
intended for use in garages, shops, light industry and on
farms. |
|
| Price Code : C | |
| MS IEC 60478-1 : 1996 | |
| Stabilized power supplies, d.c. output : Part 1 : Terms and definitions. | |
| This
Malaysian Standard applies to stabilized power supplies
designed to supply d.c. power from an a.c. or d.c. source
for applications such as, but not necessarily limited to,
the following : - computers - telecommunications - laboratories - industrial equipment. Caliberated stabilized power supplies for electrical measurement purposes are excluded from the scope of this recommendation. |
|
| Price Code : B | |
| MS IEC 60478-2 : 1996 | |
| Stabilized power supplies, d.c. output : Part 2 : Method of specifying rating and performance. | |
| This
Malaysian Standard applies to the following information
shall be permanently affixed to the power supply: (a) name of manufacturer or supplier; (b) model number; (c) serial number (optional); (d) output ratings : rating values or rated ranges of values for output voltage and current; (e) input ratings; nominal values for source voltage; source current and frequency, number of phases; (f) protection class. The performance of a stabilized power supply shall comply with the specified values of the quantities listed in the manufacture's data sheet or other documents mutually agreed on by the manufacturer and user. |
|
| Price Code : B | |
| MS IEC 60478-3 : 1996 | |
| Stabilized power supplies, d.c. output : Part 3 : Reference levels and measurement of conducted electromagnetic interference (EMI). | |
| This
Malaysian Standard specifies the measuring equipment and
techniques to be used in assessing the conducted
electromagnetic interference (EMI) generated by
stabilized power supplies and especially by switched-mode
power supplies. It also specifies the reference levels,
to be quoted by the manufacturer, of radio-frequency
interference voltage measured at the source terminals and
at the load terminals. Related mainly to power supplies
for which the source current required does not exceed
24A. The techniques employed follow the general
principles given in CISPR publications. Requirements for
measurements of radiated interference have not been
included in this standard. |
|
| Price Code : B | |
| MS IEC 60478-4 : 1996 | |
| Stabilized power supplies, d.c. output : Part 4 : Tests other than radio-frequency interference. | |
| This
Malaysian Standard applies to stabilized power supplies
designed to supply d.c. power from an a.c. or d.c. source
for applications such as, but not necessarily limited to,
the following : - computers - telecommunications - laboratories - industrial equipment. Caliberated stabilized power supplies for electrical measurement purposes are excluded from the scope of this recommendation. |
|
| Price Code : B | |
Galvanic cells and batteries |
|
Galvanic cells and batteries in general |
|
| MS 45 : 1991 | |
| Specification for batteries for automobiles (First revision). | |
| This Malaysian Standard specifies lead-acid storage butteries, hereinafter referred to as 'batteries'. with a voltage of 12 V used primarily for starting, lighting, ignition, etc. of automobiles. However, this standard is not applicable to batteries for electric vehicles and motorcycles. | |
| Price Code : C | |
| MS 277 : 1996 | |
| Specification for motorcycle batteries (Second revision). | |
| This revised Malaysian Standard specifies lead-acid storage batteries, hereinafter referred to as 'batteries', primarily for lighting, ignition, and other electrical loads of motorcycles. The purpose of this standard also specifies the characteristics and test methods relating to batteries for lighting and ignition. This standard shall supersede MS 277 : 1989. | |
| Price Code : B | |
Primary cells and batteries |
|
| MS 66 : Part 1 : 1999 | |
| Specification for primary cells and batteries : Part 1 : General (Second revision) | |
| Applies to
primary cells and batteries based on any electrochemical
system. The objects of its publication are : a) to ensure the electrical and physical interchangeability of products from different manufacturers; b) to limit the number of battery types; c) to define a standard of quality and provide guidance for its assessment; d) to provide guidance on matters of safety. These objects are achieved by specifying nomenclature, dimensions, polarity, terminals, marking, test conditions and service output requirements for each battery. This standard supersedes MS 66 : 1987. |
|
| Price Code : E | |
| MS 66 : Part 2 : 1999 | |
| Specification for primary cells and batteries : Part 2 : Specification sheets | |
| Specifies dimensions together with outline drawings of batteries, conditions and minimum duration of discharges and application. | |
| Price Code : G | |
Acid secondary cells and batteries |
|
| MS 68 : 1991 | |
| Specification for containers for lead acid batteries (First revision). | |
| This Malaysian Standard lays down the requirements and the methods of test for containers normally used in the assembly of lead-acid storage batteries. This Malaysian Standard specifies the synthetic resin and ebonite containers, hereinafter referred to as the 'container', to be used for lead-acid batteries.Remarks: The units and values used in this standard are in accordance with the International System of Units (SI) and ore appended for reference. | |
| Price Code : A | |
| MS 994 : 1990 | |
| Specification for water for lead-acid batteries. | |
| Specifies the grade A water for lead acid batteries. Also states limit of conductivity measures at 20°C. Distilled or deionized water is being used for the grade A water. | |
| Price Code : A | |
Power transmission and distribution networks |
|
Power transmission and distribution networks in general |
|
| MS 1142 : 1989 | |
| Specification for hard-drawn copper and power copper-cadmium conductors for over-head transmission purposes. | |
| Specifies requirements for hard-drawn copper and copper cadmium solid and stranded circular conductors for overhead power transmission systems. | |
| Price Code : B | |
| MS 1143 : 1989 | |
| Specification for aluminium alloy stranded conductor for overhead power transmission. | |
| Covers requirements for heat-treated aluminium-magnesium-silicon alloy stranded conductors for overhead power transmission; values for physical properties, sizes of wires and of stranded conductors; tolerances on dimensions, mechanical properties and electrical resistivity ; modules of elasticity and code names for use when ordering. | |
| Price Code : B | |
Substations. Surge arresters |
|
| MS
IEC 60335-2-15 : 2004 |
|
| Household and similar electrical appliances – Safety – Part 2-15 : Particular requirements for appliances for heating liquids | |
| This clause of part 1 is replaced by the following. This International Standard deals with the safety of electrical appliances for heating liquids for household and similar purposes, their rated voltage being not more than 250 V. | |
| Price RM160 | |
| MS IEC 61643-12 : 2004 | |
| Low-voltage surge protective devices – Part 12 : Surge protective devices connected to low-voltage power distribution systems – Selection and application principles | |
| This part of IEC 61643 describes the principles for selection, operation, location and co-ordination of SPDs to be connected to 50 Hz to Hz a.c. and to d.c. power circuits and equipment rated up to 1 000 V r.m.s. or 1 5000 V d.c. | |
Price RM240 |
|
|
Low-voltage surge protective devices – Part 21: Surge protective devices connected to telecommunications and signalling networks – Performance requirements and testing methods |
|
| This International Standard is applicable to devices for surge protection of telecommunications and signalling networks against indirect and direct effects of lighting or other transient overvoltages. | |
Price RM120 |
|
Control equipment for electric power systems |
|
| MS 925 : 1984 | |
| Specification for direct acting indicating electrical measuring instruments and their accessories. | |
| Applies to ammeters, voltmeters, single phase and polyphase watt meters for direct alternating current. | |
| Price Code : F | |
Electrical equipment for working in special conditions |
|
Electrical installations for outdoor use |
|
| MS 556 : 1989 | |
| Specification for electrical safety code of private electric generating plant (First revision). | |
| Covers electrical supply conductors, plant and equipment in electrical supply stations installed in, owned and operated by a private establishment. The purpose of this code is to safe-guard persons from hazards arising from the installation, operation and maintenance of the above. | |
| Price Code : C | |
Electrical apparatus for explosive atmospheres |
|
| MS 1591 : 2003 | |
| Electrical apparatus for explosive gas atmospheres Part 16: Artificial ventilation for the protection of analyser(s) houses | |
| This Malaysian Standard provides the general principles of protection, by artificial ventilation, of analyser(s) houses against the explosion hazards caused by internal release of flammable substances and, if applicable, against the hazards caused by an external explosive gas atmosphere. It also gives the conditions in which electrical apparatus liable to cause ignition may be used in these analyser(s) houses. These analyser(s) houses may be situated in a hazardous area or in a non-hazardous area. This Malaysian Standard contains recommendations for the construction and operation of analyser(s) houses, for their associated installations, such as air ducts, and for the auxiliary devices necessary for providing and maintaining the conditions for ventilation and, when required, pressure. This Malaysian Standard also specifies the verification and testing necessary to prove that the installation conforms to the above recommendations, and the markings to be placed on such rooms or buildings. NOTES: 1. In certain circumstances, the recommendations may be used for other buildings containing similar sources of release. 2. This standard does not deal with dangers associated with the toxicity of gases and vapours - which may be dealt with by similar techniques. It does not deal with requirements not related to explosion safety. | |
| Price Code : C | |
| MS 1592 : 2003 | |
| Electrical apparatus for explosive gas atmospheres Part 20: Data for flammable gases and vapours, relating to the use of electrical apparatus | |
| This Malaysian Standard gives guidance on the selection of appropriate electrical apparatus, protected by flame-proof enclosure or designed to be intrinsically safe, according to the gas or vapour in which it is intended to be used. Tables of chemical and engineering properties of substances are provided to assist electrical engineers in their selection of electrical apparatus to be used in hazardous areas. The scope of these data has been selected with particular reference to the use of electrical equipment in hazardous areas, and notice has been taken of standard measurement methods given in IEC-60079-1-1 and MS IEC 60079-4. Users of the data in this Malaysian Standard should be aware that all its data are the result of experimental determinations, and as such are influenced by variation in experimental apparatus and procedures, and in accuracy of instrumentation. In particular, some of the data have been determined at temperatures above ambient temperature, so that the vapour is within the flammable range. Variation in the temperature for the determination would be expected to experimental safe gap decrease with increasing temperature and/or pressure; upper revision and, where more recent information is required, the use of a maintained database is recommended (see Annex A, for information on the availability of maintained databases). NOTES: 1. The data in this Malaysian Standard has been taken from a number of references which are given in the bibliography (see Annex A). 2. Some variations in the data may appear when references are compared, but usually the discrepancy is sufficiently small to be of no importance in the selection of electrical apparatus. | |
| Price Code : D | |
| MS 1712 : 2003 | |
| Electrical apparatus for explosive gas atmospheres Classification of mixtures of gases or vapours with air according to their maximum experimental safe gaps and minimum igniting currents | |
| This Malaysian Standard provides guidance on the selection of the appropriate group or sub-group of electrical apparatus, protected by flameproof enclosure or designed to be intrinsically safe, according to the gas or vapour in which it is intended to be used. | |
| Price RM20 | |
| MS 1713 : 2003 | |
| Electrical apparatus for explosive gas atmospheres Construction and use of rooms or buildings protected by pressurisation | |
| This Malaysian Standard defines the conditions in which an electrical apparatus liable to cause an ignition may be used in a room or building where flammable gases or vapours may be present. The ingress of these gases or vapours into the room is being prevented by maintaining inside it a protective gas at a higher pressure than that of the outside atmosphere. | |
| Price RM10 | |
| MS IEC 60079-0 : 2003 | |
| Electrical apparatus for explosive gas atmospheres - Part 0 : General requirements | |
| This part of MS IEC 60079 specifies the general requirements for construction, testing and marking of electrical apparatus, Ex cable entries and Ex components, intended for use in potentially explosive atmospheres of gas, vapour and mist. This standard does not specify requirements for safety, other than those directly related to the explosion risk. | |
| Price Code : F | |
| MS IEC 60079-1 : 2003 | |
| Electrical apparatus for explosive gas atmospheres Part 1: Flameproof enclosures d | |
| This part of MS IEC 60079 contains the specific requirements for the construction and testing of electrical apparatus with the type of protection flameproof enclosure "d", intended for use in potentially explosive gas atmospheres. | |
| Price Code : F | |
| MS IEC 60079-1-1 : 2004 | |
| Electrical apparatus for explosive gas atmospheres Part 1-1 : Flameproof enclosures "d" Method of test for ascertainment of maximum experimental safe gap | |
| This part of IEC 60079 describes a test method intended for the measurement of the maximum experimental safe gas- or vapour-air mixtures under normal conditions of temperature1 and pressure so as to permit the selection of an appropriate group of flameproof enclosures. | |
| Price RM30 | |
| MS IEC 60079-2 : 2003 | |
| Electrical apparatus for explosive gas atmospheres Part 2: Pressurized enclosures p | |
| This part of MS IEC 60079 contains the specific requirements for the construction and testing of electrical apparatus with pressurized enclosures, of protection type "p", intended for use in explosive gas atmospheres. The requirements contained in this standard are supplementary to those in MS IEC 60079-0. This standard specifies requirements for pressurized enclosures containing a limited release of a flammable substance. This standard does not contain the requirements for pressurized enclosures where the containment system may release a)air with an oxygen content greater than normal, or b)oxygen in combination with inert gas in a proportion greater than 21 %. This standard does not contain requirements for pressurized rooms or analyser houses; see MS IEC 60079-13 and MS IEC 60079-16. Due to the safety factors incorporated in the type of protection, the uncertainty of measurement inherent in good quality, regularly calibrated measurement equipment is considered to have no significant detrimental effect and need not be taken into account when making the measurements necessary to verify compliance of the apparatus with the requirements of this standard. When the user acts in the role of the manufacturer, it is the user's responsibility to ensure that all relevant parts of this standard are applied to the manufacturing and testing of the apparatus. | |
| Price Code : E | |
| MS IEC 60079-4 : 2003 | |
| Electrical apparatus for explosive gas atmospheres. Part 4: Method of test for ignition temperature | |
| This method of test is intended for use in the determination of the ignition temperature of a chemically pure vapour or gas in air at atmospheric pressure. | |
| Price RM30 | |
| MS IEC 60079-5 : 2003 | |
| Electrical apparatus for explosive gas atmospheres Part 5: Powder filling q | |
| This part of MS IEC 60079 contains the specific requirements for the construction, testing and marking of electrical apparatus, parts of electrical apparatus and Ex components in the type of protection powder filling "q", intended for use in potentially explosive atmospheres of gas, vapour and mist. NOTE. Powder-filled electrical apparatus and Ex components may contain electronic circuits. transformers, protection fuses, relays, intrinsically safe electrical apparatus, associated electrical apparatus, switches, etc. This standard supplements MS IEC 60079-0, the requirements of which apply to powder-filled electrical apparatus. This standard applies to electrical apparatus, parts of electrical apparatus and Ex components with: - a rated current less than or equal to 16 A; - a rated power consumption less than or equal to 1 000 VA, intended to be connected to a supply not exceeding 1 000 V. | |
| Price Code : B | |
| MS IEC 60079-6 : 2003 | |
| Electrical apparatus for explosive gas atmospheres Part 6: Oil immersion o | |
| This part of MS IEC 60079, specifies the requirements for the construction and testing of oil-immersed electrical apparatus, oil-immersed parts of electrical apparatus and Ex components in the type of protection ''o", intended for use in potentially explosive atmospheres of gas, vapour and mist. This standard supplements MS IEC 60079-0, the requirements of which apply to oil-immersed electrical apparatus. This standard is applicable to electrical apparatus and parts of electrical apparatus which are not ignition capable in normal operation. Compliance of the electrical apparatus is to be assessed against MS IEC60079-15 except for those parts designed to comply with MS IEC 60079-11. NOTE. This standard assumes that the electrical apparatus immersed in the protective liquid is fixed in its operating position in accordance with the installation instructions. | |
| Price Code : B | |
| MS IEC 60079-7 : 2003 | |
| Electrical apparatus for explosive gas atmospheres Part 7: Increased safety e | |
| This part of MS IEC 60079 specifies the requirements for the design, construction, testing and marking of electrical apparatus with type of protection increased safety "e" intended for use in explosive gas atmospheres. This standard applies to electrical apparatus with a rated value of supply voltage not exceeding 11 kV r.m.s. a.c. or d.c. Additional measures are applied to ensure that the apparatus does not produce arcs, sparks, or excessive temperatures in normal operation or under specified abnormal conditions. These specific requirements are additional to the general requirements in MS IEC 60079-0 that apply to type of protection increased safety "e" unless specifically excluded. | |
| Price Code : G | |
| MS IEC 60079-10 : 2003 | |
| Electrical apparatus for explosive gas atmospheres Part 10: Classification of hazardous areas | |
| This part of MS IEC 60079 is concerned with the classification of hazardous areas where flammable gas or vapour risks may arise, in order to permit the proper selection and installation of apparatus for use in such hazardous areas. It is intended to be applied where there may be a risk of ignition due to the presence of flammable gas or vapour, mixed with air under normal atmospheric conditions (see note 2), but it does not apply to a)mines susceptible to firedamp; b)the processing and manufacture of explosives; c) areas where a risk may arise due to the presence of ignitable dusts or fibres; d) catastrophic failures which are beyond the concept of abnormality dealt with in this standard (see note 3); e) rooms used for medical purposes; f) areas where the presence of flammable mist may give rise to an unpredictable risk and which require special consideration (see note 5); 9) domestic premises. This standard does not take into account the effects of consequential damage. Definitions and explanations of terms are given together with the main principles and procedures relating to hazardous area classification. For detailed recommendations regarding the extent of the hazardous areas in specific industries or applications, reference may be made to the codes relating to those industries or applications. NOTES: 1. For the purpose of this standard, an area is a three-dimensional region or space. 2. Atmospheric conditions include variations above and below reference levels of 101.3 kPa (1 013 mbar) and 20 °C (293 K), provided that the variations have a negligible effect on the explosion properties of the flammable materials. 3. Catastrophic failure in this context is applied, for example, to the rupture of a process vessel or pipeline and events that are not predictable. 4. In any process plant, irrespective of size, there may be numerous sources of ignition apart from those associated with electrical apparatus. Appropriate precautions will be necessary to ensure safety in this context. This standard may be used with judgement for other ignition sources. 5. Mists may form or be present at the same time as flammable vapours. This may affect the way flammable material disperses and the extent of any hazardous areas. The strict application of area classification for gases and vapours may not be appropriate because the flammability characteristics of mists are not always predictable. Whilst it can be difficult to decide upon the type and extent of zones, the criteria applicable to gases and vapours will, in most cases, give a safe result. However, special consideration should always be given to the danger of ignition of flammable mists. | |
| Price Code : F | |
| MS IEC 60079-11 : 2003 | |
| Electrical apparatus for explosive gas atmospheres Part 11: Intrinsic safety I | |
| This part of MS IEC 60079 specifies the construction and testing of intrinsically safe apparatus, intended for use in potentially explosive atmospheres and for associated apparatus, which is intended for connection to intrinsically safe circuits which enter such atmospheres. It also contains details of the test apparatus previously published as IEC 60079-3. This standard supplements MS IEC 60079-0:1993, the requirements of which apply to intrinsically safe apparatus and to associated apparatus except as indicated in the following list. If associated apparatus is protected by a type of protection listed in IEC 60079-0 then the requirements of that method of protection together with the relevant parts of IEC 60079-0 also apply to the associated apparatus. The list of exclusions which follows is directly applicable to associated apparatus intended for use in situations where there is no potentially explosive atmosphere and in other circumstances should be used in combination with the requirements of the other methods of protection. | |
| Price Code : J | |
| MS IEC 60079-14 : 2003 | |
| Electrical apparatus for explosive gas atmospheres Part 14: Electrical installations in hazardous areas (other than mines) | |
| This part of MS IEC 60079 contains the specific requirements for the design, selection and erection of electrical installations in explosive gas atmospheres. These requirements are in addition to the requirements for installations in non-hazardous areas. This standard applies to all electrical equipment and installations in hazardous areas whether permanent, temporary, portable, transportable or hand-held. It applies to installations at all voltages. This standard does not apply to - electrical installations in mines susceptible to firedamp; NOTE. This standard may apply to electrical installations in mines where explosive gas atmospheres other than firedamp may be formed and to electrical installations in the surface installation of mines. - electrical installations in areas where the hazard is due to combustible dusts or fibres; - inherently explosive situations, for example explosives manufacturing and processing; - rooms used for medical purposes. | |
| Price Code : G | |
| MS IEC 60079-15 : 2003 | |
| Electrical apparatus for explosive gas atmospheres Part 15: Type of protection n | |
| This part of MS IEC 60079 specifies requirements for the construction, testing and marking for Group 11 electrical apparatus with type of protection "n" intended for use in explosive gas atmospheres. This standard is applicable to non-sparking electrical apparatus and also to electrical apparatus with parts or circuits producing arcs or sparks or having hot surfaces which, if not protected in one of the ways specified in this standard, could be capable of igniting a surrounding explosive gas atmosphere. A non-incendive component is limited in use to the particular circuit for which it has been shown to be non-ignition capable and, therefore, cannot be separately assessed as complying with this standard. Compliance with this standard does not imply any removal of, or lowering of, the requirements of any other standard with which the electrical apparatus complies. This standard supplements, and may enhance, the requirements for apparatus for normal industrial applications. NOTE. This standard makes several specific references to MS IEC 60079-0. It is not intended that apparatus with type of protection "n" should comply with MS IEC 60079-0 in its entirety, or that the level of protection achieved by compliance with this standard should be equal to the level of protection achieved by compliance with MS IEC 60079-0 and any of the types of protection listed therein. | |
| Price Code : H | |
| MS IEC 60079-17 : 2003 | |
| Electrical apparatus for explosive gas atmospheres Part 17: Inspection and maintenance of electrical installations in hazardous areas (other than mines) | |
| This part of MS IEC 60079 is intended to be applied by users, and covers factors directly related to the inspection and maintenance of electrical installations within hazardous areas only. it does not include conventional requirements for electrical installations, nor the testing and certification of electrical apparatus. It does not cover Group 1 apparatus (applications for mines susceptible to firedamp). This standard supplements the requirements laid down in IEC 60364-6-61. | |
| Price Code : D | |
| MS IEC 60079-18 : 2003 | |
| Electrical apparatus for explosive gas atmospheres Part 18: Encapsulation m | |
| This part of
MS IEC 60079 prescribes the specific requirements for
construction and testing of electrical apparatus, parts
of electrical apparatus and Ex components which have
rated voltages not exceeding 11 kV with the type of
protection encapsulation m. These specific
requirements supplement MS IEC 60079-0 General
Requirements with the following exceptions. Clauses
of IEC 79-0 which are not applicable : 4.2 Maximum
surface temperature (for Ex components), 5.2 Time delay
before opening an enclosure, 6.2 Threaded holes in
enclosures of plastic material, 8 Fasteners, 9
Interlocking devices, 15 Cable and conduit entries, 17
Switchgear, 18 Fuses, 20.2 Warning label for luminaires, 22.4.3.1 Test for resistance to impact (for Ex components), 22.4.4 Test for degree of protection for enclosures, 22.4.8 Test in explosive mixtures, 22.4.9 Test of clamping of non-armoured cables in cable entries, 22.4.10 Test of clamping of armoured cables in cable entries |
|
| Price Code : c | |
| MS IEC 60079-19 : 2003 | |
| Electrical apparatus for explosive gas atmospheres Part 19: Repair and overhaul for apparatus used in explosive atmospheres (other than mines or explosives) | |
| This part of MS IEC 60079: - gives instructions, principally of a technical nature, on the repair, overhaul, reclamation and modification of a certified apparatus designed for use in explosive atmospheres (other then mining applications or explosive processing and manufacture); - is not applicable to maintenance, other than when repair and overhaul cannot be disassociated from maintenance, neither does it give advice on cable entry systems which may require renewal when the apparatus is re-installed; - assumes that good engineering practices are adopted throughout. NOTE. Much of the content of this standard is concerned with the repair and overhaul of electrical rotating machines. This is not because they are the most important items of explosion-protected equipment but rather because they are often major items of repairable capital equipment in which, whatever type of protection is involved, sufficient commonality of construction exists as to make possible more detailed instructions for their repair, overhaul, reclamation or modification. | |
| Price Code : E | |
| MS IEC TS 60079-27 : 2004 | |
| Electrical apparatus for explosive gas atmospheres Part 27 : Fieldbus intrinsically safe concept (FISCO) | |
| This part of IEC 60079, which is a technical specification, contains the details of apparatus, systems and installation practice for use with the Fieldbus intrinsically safe concept (FISCO) and is based on the concepts of Manchester encoded, bus powered systems designed in accordance with IEC 61158-2 which is the physical layer standard for Fieldbus installations. | |
| Price RM30 | |
Other electrical equipment for working in special conditions |
|
| MS 477 : 1977 | |
| Code of practice for protection of electrical power equipment against climatic conditions. | |
| Applies to electrical power equipment as distinct from telecommunication and allied electric equipment except where this forms an integral part of the power equipment. No guidance is given on the special precautions necessary for equipment used in aircraft. | |
| Price Code : H | |